2.3 Power Supply Troubleshooting
E3V output
Error code Meaning
60h
61h
62h
64h
1R5-E1V output
Error code Meaning
70h
71h
72h
74h
1GD-PGV output
Error code Meaning
80h
81h
82h
PPV output
Error code Meaning
90h
91h
92h
PORTEGE A600 Maintenance Manual (960-710)
Downloaded from LpManual.com Manuals
E3V voltage is over 3.96V.
E3V voltage is under 2.81V when the computer is powered on.
E3V voltage is under 2.81V when the computer is booting up.
E3V voltage is under 2.81V when EV power is maintained.
1R5-E1V voltage is over 1.80V.
1R5-E1V voltage is under 1.275V when the computer is powered on.
1R5-E1V voltage is under 1.275V when the computer is booting up.
1R5-E1V voltage is under 1.275V when EV power is maintained.
1GD-PGV voltage is over 1.26V.
1GD-PGV voltage is under 0.425V when the computer is powered on.
1GD-PGV voltage is under 0.425V when the computer is booting up.
PPV voltage is over 1.44V.
PPV voltage is under 0.27V when the computer is powered on.
PPV voltage is under 0.59V when the computer is booting up.
2 Troubleshooting Procedures
[CONFIDENTIAL]
2-13

Advertisement