Installation; Design Criteria - Brant Radiant Heaters LD Series Operation, Installation, Maintenance And Parts Manual

Commercial, industrial, residential tube heater
Table of Contents

Advertisement

2 INSTALLATION

2.1 Design Criteria

Perimeter mounting of these infra-red heaters
provides for the most efficient installation. In figure
2.1.1, the heaters are mounted at the perimeter of the
space to be heated. Refer to the
Installation Chart for the recommended distances on
MODEL
NO.
UNITS
LD (10, 15, 20) 40 (N, P)
LD (15, 20, 30) 50 (N, P)
Note: This chart is provided as a guideline. Actual conditions may dictate variation from this data.
INFRARED
HEATER
(TYPICAL)
T
THERMOSTAT
Heater
HEATER INSTALLATION CHART
TYPICAL
MOUNTING
HEIGHT
FT.
METERS
FT.
9-16
2.7-4.9
9-26
3.0-5.2
10-17
10-28
T
COMMON
VENT
(TYPICAL)
T
TYPICAL BUILDING LAYOUT
the models being installed. Buildings that require the
rows of heaters to be farther apart than the
recommended distance in the chart may need
additional heaters placed in the center of the space.
DISTANCE
DISTANCE
BETWEEN
BETWEEN
HEATERS
HEATER ROWS
DIM "A"
DIM "B"
METERS
FT.
2.7-7.9
10-50
3.0-8.5
12-60
B
C
Figure 2.1.1
5
MAXIMUM DISTANCE
BETWEEN HEATER
AND WALL
DIM "C"
METERS
FT.
METERS
3.0-15.2
15
3.7-18.3
16
T
A
T
4.6
4.9
C