Allowance For Expansion - Brant Radiant Heaters LD Series Operation, Installation, Maintenance And Parts Manual

Commercial, industrial, residential tube heater
Table of Contents

Advertisement

2
INSTALLATION

2.12 Allowance for Expansion

Allowances must be made for the system to
expand as detailed in the Heater Expansion Chart
on this page. The supplied Type I, flexible
gas connector is recommended. If, however, local
codes require rigid piping to the heater, a swing
joint can be used.
Exchanger length and gas input will determine overall expansion. Heaters in a typical installation will expand towards both the burner and
vent ends. Review for proper flexible gas connector installation.
EXCHANGER LENGTH
FEET
/
METERS
10
3.1
10
3.1
10
3.1
15
4.6
15
4.6
15
4.6
15
4.6
20
6.1
20
6.1
30
9.2
HEATER EXPANSION CHART
FIXED OR HIGH-FIRE
GAS INPUT BTUh
25,000
30,000
40,000
25,000
30,000
40,000
50,000
40,000
50,000
50,000
23
EXPANSION LENGTH
INCHES
1/2
5/8
¾
5/8
¾
7/8
1
1
1 ¼
1 ¼
MILLIMETERS
12.7
15.9
19.1
15.9
19.1
22.2
25.4
25.4
31.8
31.8

Advertisement

Table of Contents
loading

Table of Contents