Disconnecting Hoses - Reliable Equipment REL-LP-6TN-A Operator's Manual

6 ton low pressure hydraulic crimping tool
Table of Contents

Advertisement

HOT SURFACES MAY CAUSE SERIOUS BURNS.
The hydraulic cylinder may be hot during and after operation.
CA
CA
CAUTION
CA
CA
WARNING
Never disconnect tool, hoses, or fittings while the hydraulic
power source is running or if the hydraulic fluid is hot.
Failure to observe this warning could result in serious injury.
ALWAYS CAP HOSE & TOOL CONNECTORS WHEN NOT IN USE
Turn flow control lever to the OFF position.
Turn hydraulic power source OFF.
CAUTION
CAUTION: TOOL AND/OR HYDRAULIC FLUIDS MAY BE HOT.
CAUTION: TOOL/HOSES MAY STILL BE UNDER PRESSURE.
Follow the sequence below to prevent pressure buildup.
Loosen all connections slowly in case pressure has built up.
Disconnect the pressure hose from the power source.
Disconnect the pressure hose from the tool.
Disconnect the return/tank hose from the tool.
Disconnect the return/tank hose from the power source.
Failure to fully comply could result in severe injury or death.
HOSE/CONNECTOR INSPECTION
ALWAYS DISCONNECT pump/power source and move toggle
switch to OFF before connecting or disconnecting any components.
ALWAYS DEPRESSURIZE hydraulic system, before slowly
WARNING
disconnecting this unit or any of the systems components.
ALWAYS INSPECT HOSES AND CONNECTORS. Replace or
r e p a i r i f a n y l e a k a g e i s e v i d e n t . L e a k a g e i s a s i g n o f
deterioration in component parts. Worn or leaking parts must
be repaired or replaced.
Loose or improperly tightened couplings will not allow fluid to
pass through the hose creating a blockage in the supply or
return line.
Failure to fully comply can result in severe injury or death.
SERIOUS BURN HAZARD
UTION: : : : : HYDRAULIC FLUID MAY CAUSE SERIOUS BURNS.
UTION
UTION
UTION

DISCONNECTING HOSES

13

Advertisement

Table of Contents
loading

Table of Contents