Operating Indicators

:
Green LED Indicator on top of your inverter will light to indicate power to your
inverter.
Current Overload Protection
:
If the inverter is overloaded, it will shut down to protect itself. To restore
normal operation, disconnect the excessive load and turn the unit Off and
disconnect the plug.
Low Voltage Protection
:
If the input voltage drops to 10.5V or less, the inverter will shut down to
protect the battery. To restore normal operation, return the DC input voltage
to at least 12V. The inverter will automatically return to normal operation.
High Voltage Protection
:
If the DC input voltage rises above 15 volts, the inverter will shut down to
protect itself. To restore normal operation, return the DC input voltage to less
than 15 volts. The inverter will automatically return to normal operation.
CAUTION:
Although the inverter has protection against over-voltage, it may
still be damaged if the input voltage were to exceed 16 volts.
Over Temperature Protection
:
If the inverters internal temperature rises to 104ºF, the inverter will shut down
to protect itself.
NOTE: Internal inverter temperature can rise due to being operated in a high
heat environment or due to the fan or vents being blocked during operation
(even in relatively cool outside air). To restore normal operation, turn the unit
off and allow it to cool. The inverter will automatically return to normal
operation after it has cooled.
USB Outlet
; The USB outlet will supply 5 volts at 500ma to charge and power
cell phones, iPods
and other small electronics.
®
Operating Limits
Power Output
:
The inverter can deliver 100 watts for about 60 minutes. The inverter must
cool for 15 minutes before it can resume operation at 100 watts.