Mobile Home Installation; Gas Installation; Optional Wall Switch Installation - Napoleon GD34-1NT Installation And Operating Instructions Manual

Natural gas/ propane gas fireplace napoleon
Table of Contents

Advertisement

This appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured
home or mobile home and must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard,
CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate.
A conversion kit is supplied with the mobile home appliance.
This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is
equipped with two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installations,
the fi replace must be fastened in place. Use #10 hex head screws, inserted through the holes in the base to secure. Always
turn off the pilot and the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior
to lighting the fi replace, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes.
This fi replace is only for use with the type of gas indicated on the rating plate. This fi replace is not convertible for use with
other gases, unless a certifi ed kit is used.
Conversion Kits
The mobile home appliance is fi eld convertible between Natural Gas (NG) and Propane (LP).
To convert from one gas to another consult your Napoleon® dealer/distributor.
NOTE: All gas connections must be contained within the fi replace when complete.
1. Move the fi replace into position and secure to the fl oor through the 1/4" holes
located at either side of the base.
2. The fi replace is designed to accept 3/8" gas supply line. The fi replace is equipped
with a 3/8" manual shut-off valve.
3. Connect the gas supply in accordance to local codes. In the absence thereof,
install according to the National Installation Code.
4. When fl exing any gas line, support the gas valve so that the lines are not bent
or kinked.
5. Check for gas leaks by brushing on a soap and water solution.
Purge all gas lines with the glass door of the stove removed. Assure that a continuous gas fl ow is at the burner
For ease of accessibility, an optional remote wall switch may be installed in a
convenient location. A 20ft length of millivolt wire is connected to the gas valve
for the wall switch. However, if a greater length is required route 2-strand (solid
core) millivolt wire through the electrical hole located at the bottom left side of
the unit. The recommended maximum lead length depends on wire size:
Attach the two leads to terminals 1 and 3 located on the gas valve.
Do not connect either the wall switch, thermostat or gas valve directly to
110 volt electricity.

MOBILE HOME INSTALLATION

GAS INSTALLATION

Proceed once the vent installation is complete.
DO NOT USE OPEN FLAME.
before re-installing the door.

OPTIONAL WALL SWITCH INSTALLATION

MANUAL SHUT-OFF VALVE
WIRE SIZE
LENGTH
14 Gauge
100 Feet
16 Gauge
18 Gauge
1
3
W415-0663 / A / 01.07.08
17
FIGURE 33
60 Feet
40 Feet
FIGURE 34

Hide quick links: