Gas-fired wall furnace direct vent millivolt system

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CSA 2.33 AND ANSI Z21.88 RESPECTIVELY FOR GAS-FIRED VENTED GAS FIRED SP ACE HEATING APPLIANCE
f i r e - p a r t s . c o m
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service agency
Fax: (705)722-6031
Web: www.napoleon.on.ca
CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL STANDARDS,
GAS-FIRED WALL FURNACE
DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR:
NATURAL GAS MODEL
PROPANE GAS MODEL
FOR YOUR SAFETY
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
or the gas supplier.
Wolf Steel Ltd., RR#1, 9 Napoleon Rd.,
Barrie, ON., Canada L4M 4Y8 (705)721-1212
Email: ask@napoleon.on.ca
GD3200-N / GD3200B-N
GD3200-P / GD3200B-P
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier,
call the fire department.
R-2000
WS-415-53 / 04.08.99

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GD3200-N

  • Page 1 • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Wolf Steel Ltd., RR#1, 9 Napoleon Rd., Barrie, ON., Canada L4M 4Y8 (705)721-1212 Fax: (705)722-6031 Email: ask@napoleon.on.ca R-2000 Web: www.napoleon.on.ca...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-5 INTRODUCTION PG 16 OPTIONAL BLOWER INSTALLATION Warranty OPTIONAL FAN & THERMOSTATIC SENSOR General Instructions 18-19 OPERATION / MAINTENANCE General Information Care of Glass & Plated Parts Operating Instructions VENTING Maintenance ADJUSTMENTS f i r e - p a r t s . c o m Vent lengths Special Installation Example Pilot Burner Adjustment...
  • Page 3 NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPO- LEON will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install to the current CAN/CGA -B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1-1988, and NFPA 54-1988 in the United States. Suitable for mobile home installation if installed in accordance with the current standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1-1988 and NFPA 54-1988 in the United States.
  • Page 5: General Information

    Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. If the door glass should crack or break, do not operate the fireplace.
  • Page 6: Special Installation Example

    A L T H O U G H T H E I M M E D I A T E V E R T I C A L R U N M A Y B E G R E A T E R T H A N 5 7 I N C H E S , T H E MAXIMUM COMBINATION OF HORIZONTAL AND VERTICAL RUNS, BEYOND THE 57 INCHES, MUST NOT EXCEED 20 FEET. Only the following Napoleon Vent Kits, used in combination with each other can be FIGURE 5 used:...
  • Page 7 AIR TERMINAL INSTALLATIONS: FIGURE 6 INSTALLATIONS CANADIAN U.S.A. 12 INCHES 12 INCHES Clearance above grade, veranda porch, deck or balcony. 12 INCHES 9 INCHES Clearance to windows or doors that open. f i r e - p a r t s . c o m 12 INCHES* 12 INCHES* Clearance to permanently closed windows.
  • Page 8 VERTICAL INSTALLATION: This application occurs when venting through a roof. FIGURE 2. Installation kits for various roof pitches are available from your Napoleon dealer. See Accessories to order the specific kit required. 1. Determine the air terminal location, cut and frame 9½ inch openings in the ceiling and the roof to provide the minimum 1 inch clearance between the fireplace pipe / liner and any combustible material.
  • Page 9 FIGURE 13. The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Napoleon support ring assembly GA-GD-010.370 or equivalent noncombustible strapping to main- tain the minimum 1" clearance to combustibles.
  • Page 10 VERTICAL VENTING INSTALLATION FIGURE 14 1. Fasten the roof support to the roof using the screws FIGURE 15 provided. The roof support is optional. In this case the vent- ing is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 11 HORIZONTAL RUNS MUST HAVE A ¼ INCH RISE PER FOOT The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Napoleon vent spacers WS-615-33 or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes.
  • Page 12: Installation / Framing

    INSTALLATION / FRAMING INSTALLATION Proceed once the vent installation is complete. 1. Route a 3/8" N.P.T. black iron gas line, 1/2" type-L copper tubing or equivalent to the fireplace. 2. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location.
  • Page 13: Framing

    FRAMING OUTSIDE CHASE INSIDE CHASE FIGURE 23 FIGURE 24 FIGURE 22 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. FIGURE 22-24. To install the fireplace face flush with the finished wall, position the framework to accomodate the thickness of the finished wall.
  • Page 14: Finishing

    LOG PLACEMENT INSTRUCTIONS / CHARCOAL EMBERS PHAZER logs and charcoal embers, exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the charcoal embers for a maximum glowing effect.
  • Page 15 Centre both side trims. FIGURE 31 LOUVRES: The louvre assemblies are installed as illustrated in FIGURE 31. Optional arched door facias and black webbed facias are available at your local Napoleon/ Wolf Steel dealer. GD3200B DOOR REMOVAL: To access the firebox, remove the two screws securing the bay window facade assembly in place.
  • Page 16: Optional Blower Installation

    OPTIONAL BLOWER INSTALL ATION INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996 in the United NATIONAL ELECTRICAL CODE States.
  • Page 17 GD36 THERMOSTATIC SENSOR CONTROL This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown above, which may be ordered from your Wolf Steel / Napoleon dealer. THERMODISC With the thermostatic sensor option, the fan, when turned on, becomes ther-...
  • Page 18: Operation / Maintenance

    OPERATION / MAINTENANCE OPERATING INSTRUCTIONS When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.
  • Page 19: Maintenance

    6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer / distributor.
  • Page 20: Replacements

    ORDERING REPLACEMENT P ARTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
  • Page 21: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE A TTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALL Y LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM TEST SOLUTION Main burner flame Blockage in vent. - remove blockage. In really cold conditions, ice buildup may occur is a blue, lazy, on the terminal and should be removed as required.
  • Page 22 SYMPTOM PROBLEM TEST SOLUTION - connect a jumper wire across the wall switch terminals; if main Themostat or switch is de- Pilot burning; no burner lights, replace switch / thermostat. fective. gas to main burner; gas knob is on 'HI'; Wall switch wiring is defec- - connect a jumper wire across terminals 1 &...
  • Page 23 NOTES: f i r e - p a r t s . c o m WS-415-53 / 04.08.99...