Advertisement

CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33 ● ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
GD36NTR
BGD36NTR
NATURAL GAS MODEL
GD36PTR
BGD36PTR
PROPANE GAS MODEL
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions are
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
-
Installation
and
performed by a qualified installer, service
agency or the supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
OPERATION INSTRUCTIONS
service
must
be
www.napoleonfireplaces.com • ask@napoleon.on.ca
INSTALLATION
1
AND
W415-0210 / Q / 01.17.08

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GD36NTR

  • Page 1 Installation service must performed by a qualified installer, service agency or the supplier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www.napoleonfireplaces.com • ask@napoleon.on.ca $10.00 W415-0210 / Q / 01.17.08...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Minimum Enclosure Clearances PG 2-5 INTRODUCTION Minimum Mantel Clearances Warranty Nailing Tab Installation General Instructions 27-28 FINISHING General Information Care of Glass and Plated Parts Door Removal & Installation Specifi cations Door Glass Replacement L36 Louvre Installation 5-16 VENTING Log Placement...
  • Page 3 ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® W415-0210 / Q / 01.17.08...
  • Page 4: General Instructions

    Never obstruct the front opening of the fi replace. Objects placed in front of the fi replace must be kept a minimum of 48" away from the front face of the unit. Use only Napoleon® accessories designed for and listed with the model. W415-0210 / Q / 01.17.08...
  • Page 5: Care Of Glass And Plated Parts

    3/16" Ceramic Glass* 3/16" Tempered Glass* plated parts. Buff *Available from your Napoleon® / Wolf Steel Ltd. dealer. lightly with a clean dry cloth. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi...
  • Page 6: Vent Installations

    For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the fi...
  • Page 7: Typical Vent Installations

    TYPICAL VENT INSTALLATIONS (GD36 AND BGD36) REAR EXIT TOP EXIT 16” 16” MINIMUM MINIMUM FIGURE 2a FIGURE 2b 40 FT MAXIMUM 40 FT MAXIMUM 3 FT MINIMUM 3 FT MINIMUM GD36 BGD36 100" MAXIMUM 20" MAXIMUM 20" MAXIMUM 50" MAXIMUM 24"...
  • Page 8: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 5 W415-0210 / Q / 01.17.08...
  • Page 9 W415-0210 / Q / 01.17.08...
  • Page 10 DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calculations feet inches and examples are: 1° 0.03 > - greater than 15° 0.45 > - equal to or greater than 30° 11.0 < - less than 45°...
  • Page 11 TOP EXIT / HORIZONTAL TERMINATION ) > (V FIGURE 8 FIGURE 8 Simple venting confi guration (only one 90° elbow) 90° FIGURE 9 See graph to determine the required Example 2: vertical rise V for the required = 6 ft horizontal run H = 3 ft GD36...
  • Page 12 REAR EXIT / HORIZONTAL TERMINATION Example 4: ) < (V 90° Simple venting confi guration (only two 90° elbows) 90° 90° FIGURE 11 FIGURE 12 90° = 9 ft See graph to determine the required vertical rise V for the = 6 ft required horizontal run H = 9 + 6 = 15 ft...
  • Page 13 REAR EXIT / HORIZONTAL TERMINATION Example 5: ) > (V 90° FIGURE 13 90° 45° 90° Simple venting confi guration (only two 90° elbows) 90° See graph to determine the required vertical rise V for the required horizontal run H FIGURE 14 REQUIRED = 4 ft...
  • Page 14 TOP OR REAR EXIT VERTICAL TERMINATION Example 6: ) < (V FIGURE 16 90° FIGURE 15 90° Simple venting confi gurations 90° 90° See graph to determine the required vertical rise V for the = 5 ft required horizontal run H = 6 ft = 10 ft REQUIRED...
  • Page 15 TOP OR REAR EXIT VERTICAL TERMINATION Example 7: ) > (V = 2 ft Simple venting confi gurations = 1 ft = 1.5 ft = 2 + 1 + 1.5 = 4.5 ft = 6 ft = 2 ft = 6 + 2 = 8 ft = .03(four 90°...
  • Page 16: Pre-Installation Preparation

    PRE-INSTALLATION PREPARATION FAILURE TO INSTALL THE CAP WILL CAUSE THE FIREPLACE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE. SEE TOP EXIT PREPARATION FOR DETAILS. GD36 BGD36 REAR EXIT REAR EXIT Remove the baffl e from the back of the fi rebox by removing From inside the firebox, insert the 4"...
  • Page 17: Installation

    INSTALLATION WALL AND CEILING PROTECTION For optimum performance it is recommended that all horizontal runs have a minimum 1" rise per foot using fl exible venting. For safe and proper operation of the fi replace, follow the venting instructions exactly. HORIZONTAL INSTALLATION GD36 FIRESTOP SLEEVE ASSEMBLY 1.
  • Page 18: Vertical Installation

    fi restop assembly. Dry fi t the fi restop assembly before proceeding to ensure the brackets on the rear surface fi t within the horizontal framing. As an alternative to framing, the vent pipe/liner can be enclosed in the wall using Napoleon ® vent sleeve VS47KT. NOTE: THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.
  • Page 19: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS For safe and proper operation of the fi replace, follow the FIGURE 31 venting instructions exactly. All 4" fl ex vent pipe and 7" fl ex vent pipe joints may be ELBOW sealed using high temperature sealant W573-0002 (not supplied) or the high temperature sealant W573-0002 SPACERS Mill Pac (not supplied).
  • Page 20: Fireplace Vent Connection

    W615-0033 every 3 feet on either side of each elbow CAULKING to maintain the minimum 1¼" clearance between the 7" rigid HI-TEMP vent pipe and 4" rigid vent pipes. Use Napoleon® support ring SEALANT 4"RIGID assembly W010-0370 or equivalent noncombustible strapping VENT 7"RIGID...
  • Page 21 HORIZONTAL AIR TERMINAL INSTALLATION 1. Move the fi replace into position. Measure the vent length required between terminal and fi replace taking into account the additional length needed for the fi nished wall surface and any 1¼" overlaps between venting components. 2.
  • Page 22: Restricting Vertical Vents

    Conversion Kits The mobile home appliance is fi eld convertible between Natural Gas (NG) and Propane (LP). To convert from one gas to another consult your Napoleon® dealer/distributor. GAS INSTALLATION Proceed once the vent installation is complete.
  • Page 23 GD36 FRAMING It is best to frame your fi replace after it is positioned and the Minimum clearance to combustible construction from vent system is installed. Frame to local building codes. fi replace and vent surfaces: It is not necessary to install a hearth extension with this Combustible Framing: fi...
  • Page 24 BGD36 FRAMING It is best to frame your fi replace after it is positioned and the Minimum clearance to combustible construction from vent system is installed. Frame to local building codes. fi replace and vent surfaces: It is not necessary to install a hearth extension with this Combustible Framing: fi...
  • Page 25: Minimum Enclosure Clearances

    MINIMUM ENCLOSURE CLEARANCES GD36 BGD36 REAR EXIT ENCLOSURE REAR EXIT ENCLOSURE COMBUSTIBLE NON-COMBUSTIBLE COMBUSTIBLE NON-COMBUSTIBLE ” MINIMUM BRICK BRICK 6” MINIMUM 0” IF 0” IF NON-COMBUSTIBLE NON-COMBUSTIBLE FINISHING IS USED FINISHING IS USED SUCH AS BRICK SUCH AS BRICK 2” 2”...
  • Page 26: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES Combustible Mantel clearance can vary according to the Mantel depth. Use the graph to help evaluate the clearance needed. These same requirements apply to any combustibles protruding on either side of the fi replace. FIGURES 51 a&b 8"...
  • Page 27: Finishing

    HOOD HOOD the top and bottom door latches, located at the right side of the door. UPPER UPPER Optional plated door trim, and arched door facia are available at your local Napoleon LOUVRE LOUVRE dealer. FIGURE 54 NOTE: The protective wrap on plated parts is best removed when the assembly is at room...
  • Page 28: Log Placement

    LOG PLACEMENT PHAZER logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fi replace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.
  • Page 29: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION BLOWER white FIGURE 61 THERMODISC FIGURE 62 Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the securing VARIABLE stud at the bottom left of the unit using a lock washer and wing FIGURE 59 SPEED nut.
  • Page 30: Optional Fan Installation

    Use of the fan increases the output of heat. the GD65 Fan Kit, shown above, which may be ordered from Unplug the power cord from the receptacle. Connect all wires your Wolf Steel / Napoleon dealer. as shown. Attach and secure the sensor assembly bracket to the secur-...
  • Page 31: Maintenance

    If ignition takes longer, consult obstructed. your Napoleon dealer / distributor. 7. Check that the gasketing on the sides, top and bottom of the door 1. In order to properly clean the burner and pilot assembly, remove is not broken or missing.
  • Page 32: Adjustments

    ADJUSTMENTS PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn Both fi replace models have air shutters that have been factory in a clockwise direction to reduce the gas fl ow. set open according to the chart below: FIGURE 69 GD36 BGD36...
  • Page 33: Replacements

    Contact your dealer for questions concerning prices and availability WARNING of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. Failure to position the parts in accordance with these diagrams or When ordering replacement parts always give the following...
  • Page 34 GD36 COMPONENTS BGD36 COMPONENTS W455-0017 #42 NATURAL GAS ORIFICE W455-0048 #47 NATURAL GAS ORIFICE W455-0003 #54 PROPANE GAS ORIFICE W455-0047 #56 PROPANE GAS ORIFICE W361-014 VERMICULITE W010-1774 FIRESTOP SPACER W010-1777 FIRESTOP SPACER BGD36 ACCESSORIES GD36 ACCESSORIES W175-0158 CONVERSION KIT - NG TO LP W175-0159 CONVERSION KIT - NG TO LP W175-0163...
  • Page 35: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN SYMPTOM PROBLEM TEST SOLUTION Main burner goes Pilot fl ame is not large enough - turn up pilot fl ame. out;...
  • Page 36 SYMPTOM PROBLEM TEST SOLUTION Pilot goes out while Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or s t a n d i n g ; M a i n extinguishes, especially when main burner ignites.