Digital air- conditioner controller KR- 454
PROGRAM 5:
This test program is used to test the valves.
Assignment of the valves:
1:
2:
3:
4:
5:
6:
You can quit the test program by pressing key S6 ( AUTO ).
PROGRAM 6:
This displays the temperatures of all sensors.
Assignment of the sensors:
sensor 1:
sensor 2:
sensor 3:
sensor 4:
sensor 5 :
sensor 6:
sensor 7:
sensor 8:
Fühler 9:
Fühler 10 (A):
Fühler 11 (b):
You can quit the test program by pressing key S6 ( AUTO ).
PROGRAM 7:
INDUSTRIE-ELEKTRONIK
You can select valves 1...6 with keys S12 and S13. The valve
number is displayed on the left on the display, and the valve
setting from 0% to 100% is displayed on the right.
You open or close each of the selected valves by pressing keys
S15 and S16 (driver's cockpit temperature).
(Normal angle: about 7% - 87%
roof valve upper deck
roof valve lower deck
valve front box driver's cockpit
valve front box upper deck
convector valve lower deck
convector valve upper deck
You can select the sensors 1...11 with keys S12 and S13. The
number of the sensor is displayed on the left on the display. The
sensor temperature is displayed on the right.
outside temperature
passenger compartment lower deck
roof duct lower deck
convector lower deck
passenger compartment upper deck
roof duct upper deck
convector upper deck
convector upper deck rear
setpoint front box upper deck
Reserve
Reserve
Control and regulating systems for vehicle air conditioning
D-71691 Freiberg a.N.,
Phone: +49 7141 / 68877 - 0
Issue: October 1998 - Copyright (C) BADER GmbH - Alterations reserve