Setting The Time - Bader KR-454 Operating Instructions Manual

Air conditioner controller
Table of Contents

Advertisement

Digital air- conditioner controller KR- 454
S11
S12
S13
S14

3.3 SETTING THE TIME

S14
INDUSTRIE-ELEKTRONIK
CONVECTORS
This key can be used to switch the convectors on and off. They
are also controlled via their own sensor in Ventilation mode,
dependent on the set temperature (setpoint keys S17, S18, S19,
S20). The measured passenger compartment temperature is used
as the basis for limiting the temperature for convector control.
PASSENGER COMPARTMENT TEMPERATURE UPPER DECK
AND SETTING THE TIME
When setting the time and the time switch, this key is used to
increment (count up) the hours display. In
this key is used to increment the diagnostic steps.
PASSENGER COMPARTMENT TEMPERATURE LOWER DECK
AND SETTING THE TIME
When setting the time and the time switch, this key is used to
increment (count up) the minute display. In Diagnostic mode, this
key is used to decrement (count down) the diagnostic steps.
OUTSIDE TEMPERATURE
With ignition switched on:
-The outside temperature is displayed.
-The current time is displayed after you press the function key.
With ignition switched off:
-Activating Clock-set mode
-Confirm key for new time entered.
OUTSIDE TEMPERATURE/TIME
Control and regulating systems for vehicle air conditioning
D-71691 Freiberg a.N.,
Phone: +49 7141 / 68877 - 0
Issue: October 1998 - Copyright (C) BADER GmbH - Alterations reserve
Diagnostic
Siemensstr.21
Fax: +49 7141 / 68877 - 39
mode,
page:
11
of:
42
04541530.SDW

Advertisement