Non-programmable thermostat builder series

Advertisement

Quick Links

Builder Series
Non-Programmable Thermostats
MODEL
Heat Only or Cool Only Thermostat
1005
Before Installing, Programming or Operating,
PLEASE READ ALL INSTRUCTIONS
Specifications
1
Installation
2
Testing Your New Thermostat
3
Programming User Settings
4
Temperature Adjustment
5
WARNING

Important Safety Information

• Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating this
thermostat.
• This thermostat is designed for use with a 24 Volt-AC low voltage single stage gas,
oil or electric heating or cooling systems. This thermostat can also be used on
250mv to 750mv millivolt heating only systems.
• Do not use this thermostat on applications with voltages above 30 Volts AC.
• This thermostat requires two (2) properly installed "AA" alkaline batteries to
provide power for the thermostat to properly control the system operation.
• The system must have 24 Volt AC power present for proper system operation and control.
• Wiring must conform to all building codes and ordinances as required by local and
national code authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could
damage the thermostat and void the warranty.
• Do not operate compressor if the outside temperature is below 50˚ F (10˚ C).
This could possibly damage the controlled cooling system and may cause
personal injury.
• This thermostat should only be used as described in this manual. Any other use is
not recommended and will void the warranty.
TM
Additional Operation
6
Features
Battery Replacement
7
Troubleshooting
8
Wiring Diagrams
9
1
Specifications
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
• Compatibility with low voltage single stage gas, oil or electric heating or cooling
systems. This thermostat can also be used on 250mv to 750mv millivolt heating
only systems.
• Terminations: R, W/Y, G
2
Installation
Replacing Existing Thermostat
1. Always turn off power to the air conditioning or heating system prior to removing existing
thermostat.
2. Remove the cover of your old thermostat and locate the wire terminals. Do not remove
wires from terminals until step 4.
3. Using small pieces of masking tape label wires prior to removal from terminals. Use the
chart below to determine the new terminal designations for your new thermostat.
Old Terminal from
New Terminal for
Existing Thermostat
New Thermostat
V, Rc, M, 4, Rh or R
Y, H, W or 4
G or F
4. After labeling and removing all wires from terminals, unscrew the existing thermostat
sub-base from wall. Make sure to secure wires to prevent them from slipping
back into the hole in the wall.
NOTE:
This thermostat is designed for use with a 24 Volt-AC low voltage
single-stage gas, oil or electric heating or cooling systems. This thermostat can also
be used on 250mv to 750mv millivolt heating only systems. Do not use this
thermostat on applications with voltages above 30 Volts AC.
Installing Your New Thermostat
NOTE:
If you are installing this thermostat in a new installation be sure to locate
the thermostat 4 to 5 feet above the floor in accordance with applicable building
codes. Make sure to install the thermostat in a location that provides good airflow
characteristics and avoid areas behind doors, near corners, air vents, direct sunlight
or near any heat generating device. Installation in any of these areas could impact
thermostat performance.
1. Always turn off power to the air conditioning or heating system prior to installing your
new thermostat.
2. Place system switch on front of thermostat to OFF position.
3. Place fan control switch on front of thermostat to AUTO position.
4. Remove front of thermostat body from sub-base by pressing release latch on bottom
of front body.
5. Place the thermostat sub-base against wall in the desired thermostat location.
6. Guide thermostat wires through center hole in sub-base. Continue to hold sub-base
against wall.
7. Mark placement of mounting holes as appropriate and drill using a 3/16" drill bit.
8. Gently tap supplied plastic anchors into the holes in the wall.
9. Place the thermostat sub-base against the wall in the desired location, making sure
the mounting holes are aligned as appropriate and the thermostat wires are properly
inserting through opening in middle of sub-base.
Terminal Description
R
Cooling or Heating Transformer
W/Y
Heating or Cooling
G
Fan Control
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Builder 1005 and is the answer not in the manual?

Questions and answers

Summary of Contents for Braeburn Builder 1005

  • Page 1: Important Safety Information

    Specifications • Electrical Rating: 24 Volt AC (18-30 Volt AC) Builder Series 1 amp maximum load per terminal 2 amp total maximum load (all terminals) Non-Programmable Thermostats • Control Range: 45˚ - 90˚ F (7˚ - 32˚ C) • Accuracy: +/- 1˚ F (+/- .5˚ C) •...
  • Page 2: Installation

    Installation Testing Your New Thermostat cont. cont. Installing Your New Thermostat cont. 5. The cooling system should start within several seconds. Place the system switch in the OFF position. The cooling system should stop within a few seconds. 6. Place the fan switch in the ON position. The system blower should start. 10.
  • Page 3: Temperature Adjustment

    Temperature Adjustment Additional Operation Features cont. Review Set Temperature Low Battery Detection 1. Press and hold button. The current set point This thermostat requires two (2) properly installed "AA" alkaline batteries to provide power temperature will be displayed in place of the for the thermostat to properly control the system operation.
  • Page 4: Troubleshooting

    Troubleshooting Troubleshooting cont. SYMPTOM POTENTIAL SOLUTION SYMPTOM POTENTIAL SOLUTION Thermostat does not Check to see if OFF is shown in display. This indicates that the HI is shown in the The temperature sensed by the thermostat is higher than the turn on heating or system is turned off at the thermostat.
  • Page 5: Wiring Diagrams

    Heat or Cool Braeburn installation and operating instructions. Control Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat Hot Side under warranty provided it is returned postage prepaid to our warranty facility in a padded...