Adjustments - Superior DRT4040DMN Installation And Operation Instruction Manual

Superior drt40 series direct vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT40 Direct Vent Gas Fireplace
TM
Burner Flame Adjustments
WARNING
• Air shutter adjustment should
only be performed by a quali-
fied professional service tech-
nician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTION
• Soot will be produced if the
air shutter is closed too much.
Any damage due to sooting,
resulting from improperly
setting the air shutter, is not
covered under the warranty.
• The air shutter door and
nearby appliance surfaces
are hot. Exercise caution to
avoid injury while adjusting
flame appearance.
1. Refer to Figures 74 and 75 for proper flame
appearance. To adjust the flame, rotate the
adjustment rod toward the back or toward
the front of the fireplace (rod located in the
lower control area). Position the air shutter
to the factory setting as shown in the table
in Figure 76.
2. Light appliance (follow lighting procedure
on lighting label in control compartment or
see the Pages 55 through 58.
3. Allow the burner to operate for at least 15
minutes while observing the flame continu-
ously to ensure that the proper flame ap-
pearance has been achieved. If the following
conditions are present, adjust accordingly.
• If flame appears weak or sooty, adjust
the air shutter, incrementally, to a more
open position until the proper flame
appearance is achieved.
• If flame remains blue, adjust the air
shutter, incrementally, to a more closed
position until the proper flame appear-
ance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (and remote switches, if applicable).
5. When satisfied that the burner flame appear-
ance is normal, re-install the lower control
compartment door then proceed to finish
the installation.
Burner
Venturi
Tube
Air Shutter
Opening
Decrease
Increase
Air Shutter
Air Shutter
Opening
Opening
Air Shutter
Adjusting
Arm
Main Burner
Factory Shutter Opening Setting
Natural Gas
Models
inches (mm)
EDV40
EDV45
1/8 (3.2)
Figure 76
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot flame.
The flame should project 1" (25 mm) beyond
the hood at all three ports (see Figure 77).
Replace logs if removed for pilot inspection.
To light the burner; turn "ON" the remote wall
switch and rotate the gas valve control knob
counterclockwise to the "ON" position ("ON"
will be at the top side of the valve).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MILLIVOLT
Thermocouple
Air
Shutter
Door
Pilot
Nozzels
Orifice
Figure 77 - Millivolt Pilot
Electronic Appliance Checkout
To light the burner, turn 'ON' the wall or remote
control switch. Ensure the igniter lights the pilot.
The pilot flame should engulf the flame rod as
shown in Figure 78.
Propane Gas
inches (mm)
3/8 (9.5)
Sensor
Flame Rod
(sensor)
Figure 78 - Electronic Pilot
Installation and Operation Instructions
900357-00, 06/2015
Hood
Igniter Rod
3/8" Min
(9 mm)
Thermopile
Igniter
Igniter
Pilot
Hood
Pilot Hood
49