Innovative Hearth Products
Superior
DRT40 Direct Vent Gas Fireplace
TM
FIREPLACE AND FRAMING SPECIFICATIONS
A
Models
in.
41-1/4
40"
mm
1048
in.
46-1/2
45"
mm
1175
Efficiencies %
Natural Gas
Models
AFUE
40"
67
45"
67
Vent Size
Co-axial DV
4-1/2" Inner
Vent Size
7-1/2" Outer
Based on CSA P.4.1-09
NOTES
Diagrams, illustrations and pho-
tographs are not to scale - consult
installation instructions. Product
designs, materials, dimensions,
specifications, colors and prices
are subject to change or discontinu-
ance without notice.
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to locate
center of the vertical run. Cut and/or frame an
opening, 10-1/2" x 10-1/2" (267 mm x 267
mm) inside dimensions, about this center
mark (see Figure 19).
WARNING
Failure to position the parts in
accordance with these diagrams
or failure to use only parts specifi-
cally approved with this appliance
may result in property damage or
personal injury.
AVERTISSEMENT
Risque de dommages ou de
blessures si les pièces ne sont
pas installées conformément à
ces schémas et ou si des pièces
autres que celles spécifiquement
approuvées avec cet appareil sont
utilisées.
Figure 14
12
Framing
B
C
C
D
(rear vent)
(top vent)
40-1/4
20-7/8
23-5/8
27-1/2
1022
530
600
699
40-1/4
20-7/8
23-5/8
27-1/2
1022
530
600
699
Propane
P4
AFUE
P4
60
67
63
63
68
65
Input (BTU/HR) - MV & Electronic
Input Rate (BTU / HR)
Models
Nat. Gas
Prop. Gas
40"
27,000
27,000
45"
31,000
29,000
Rear/Side
Framing
Spacers
Header
Spacing
Top
Standoff
F
Model
40"
45"
Vent Framing - Top Vent
With One 90º Elbow
E
43-5/8
1108
Vent Framing - Rear Vent
With no Elbows
43-5/8
1108
B
¹⁄₂ A
Inches (mm)
M
N
Concentric Flue:
Flue 4-1/2" (114 mm);
Combustion Air
7-1/2" (190 mm).
10-7/8
(275)
Top View
4 (102)
K
H
G
J
Front View
Gas control
access panel
F
G
H
in.
41-1/8
37 1/8"
24
mm
1045
943
609
in.
41-1/8
37 1/8"
24
mm
1045
943
609
Installation and Operation Instructions
Framing should be constructed
of 2x4 or larger lumber.
10-1/2
(
)
267
(178)
5-1/8
(130)
7
(178)
5-1/8
E
(130)
D
C
A
C is the required framing depth dimension when the
finish material(drywall) thickness is 1/2" (13mm)
Viewable Glass Size
40" Model
45" Model
20-7/8
2 (52)
(531)
Hood
Front Face
Assembly
and Barrier
GAS INLET
10-1/8
(either side
(257)
and bottom)
3 (76)
7
179)
(
J
K
L
M
34-1/2
40-1/8
27-1/2
26-1/2
876
1019
698
675
39-1/2
45-1/8
27-1/2
31-1/2
1003
1146
698
802
900357-00, 06/2015
7
12-1/8
(308)
12-1/8
(308)
34-1/2" Wide
24" High
39-1/2" Wide
24" High
1/2 (13)
L
Electrical
Inlet
Right Side View
N
13-3/4
337
15-3/4
401