Step 5. Field Wiring - Superior DRT4040DMN Installation And Operation Instruction Manual

Superior drt40 series direct vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT40 Direct Vent Gas Fireplace
TM

Step 5. FIELD WIRING

CAUTION
Ground supply lead must be con-
nected to the wire attached to the
green ground screw located on the
outlet box. See
Figure 47
do so will result in a potential safety
hazard. The appliance must be
electrically grounded in accordance
with local codes or, in the absence of
local codes, the National Electrical
Code, ANSI/NFPA 70-latest edition.
(In Canada, the current CSA C22.1
Canadian Electrical Code).
CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors can
cause improper and dangerous operation.
ATTENTION: Au moment de l'entretien des
commandes, étiquetez tous les fils avant de
les débrancher. Des erreurs de cáblage peu-
vent entraîner un fonctionnement inadéquat
et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
APPLIANCE- MOUNTED
ON/OFF SWITCH
(OPTIONAL)
TP-TH
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
FAN
(OPTIONAL)
Figure 46
26
Refer to Section A for millivolt appliances and
Section B for electronic appliances. The gas
valve is set in place and pre-wired at the factory
on both models.
A. Millivolt Wiring (See Figure 46) -
1. Appliance-mounted ON/OFF burner control
switch (rocker switch) is factory installed
. Failure to
in the control compartment. Optional wall-
mounted switch, thermostat, or one of the
optional remote control kits may also be
used.
2. If wall-mounted ON/OFF control switch or
thermostat is selected, mount it in a conve-
nient location on a wall near the fireplace.
3. Wire the control switch within the millivolt
control circuit using the 15 feet of 2 conductor
wire supplied with the unit.
NOTE: The supplied 15 feet of 2 conductor
wire has one end of each conductor con-
nected to the gas valve circuit and the other
end of each conductor placed loose inside
the bottom compartment.
CAUTION: Do Not connect the optional wall
switch to a 120V power supply.
4. If an optional control switch is installed,
turn the appliance-mounted ON/OFF burner
control switch to the OFF position.
TP
TH
GAS VALVE
OPTIONAL
REMOTE RECEIVER
ON/OFF SWITCH
WALL SWITCH
WIRING COLOR CODE
B = BLACK
BR = BROWN
GY = GRAY
PU = PURPLE
R = RED
P/N 580491-01
Figure 47 - Wiring Diagram - Electronic Gas Valves
BK
R
W
GR
JUNCTION BOX
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
JUNCTION BOX
120V AC
HOT
B
NEUTRAL
W
GROUND
G
LIMIT SWITCH
B-VENT MODELS
ONLY
R
BL = BLUE
G = GREEN
O = ORANGE
W = WHITE
Y = YELLOW
SCHEMATIC REPRESENTATION ONLY
Installation and Operation Instructions
B. Electronic Wiring
One of the following optional controls also may
be used: ON/OFF Wall Switch, Thermostat,
Remote Control (see fireplace Care and
Operation Instructions for details).
NOTE: Electronic models must be connected
to the main power supply.
1. Route a 3-wire 120Vac 60Hz 1ph power
supply to the appliance junction box.
2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's
securing screws.
3. Remove the cover plate knockout; then
feed the power supply wire through the
knockout opening and into the unit junction
box.
4. See Figure 47. Connect the black power
supply wire to the lower outlet's red pigtail
lead.
Connect the white power supply wire to the
outlet's common terminal.
5. Connect the ground supply wire to the
pigtail lead attached to the outlet's green
ground screw.
AC/DC
POWER
ADAPTOR
Y
G
PROFLAME VALVE
PILOT TUBE
O
SPARK WIRE CABLE
PILOT GROUND WIRE
B
B
W
R
BL
BATTERY HOLDER
900357-00, 06/2015
(Figure 47)
ELECTRONIC PILOT ASSEMBLY
IGNITER ROD
HOOD
FLAME SENSOR
B
PILOT
B
SENSOR
Y
CABLE
Y
G
O
W
PROFLAME DFC BOARD
BL
B
R
G
B
R
DFC WIRE HARNESS
OPTIONAL CPI SWITCH
OFF (O) = INTERMITTENT PILOT MODE
ON (-) = STANDING PILOT MODE