REFRIGERANT SYSTEM DIAGRAM

MCFH-13NV -
E3
INDOOR UNIT
Indoor
heat
Distributor
exchanger
Coil temperature
thermistor
RT12
Room temperature
thermistor
RT11
MAX. REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE
Model
MCFH-13NV -
E3
MAX. HEIGHT DIFFERENCE
Height difference should be within
5m regardless of which unit,
indoor or outdoor position is high.
ADDITIONAL REFRIGERANT CHARGE (R-22 : g)
Model
MCFH-13NV -
E3
Refrigerant pipe [12.7
(Option)
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe
(Option)
[6.35
(with heat insulator)
Length : m (ft)
A
15(49)
A: Refrigerant piping
Max.length
15m(49ft)
Outdoor unit precharged
1,350
Reversing valve
Muffler
Accumulator
Strainer
Piping size O.D : mm(in.)
Gas
[12.7(1/2)
Refrigerant piping length (one way)
7m
8m
9m
10m
0
100
50
150
8
MUCFH-13NV -
OUTDOOR UNIT
Outdoor
heat
Strainer
exchanger
Compressor
Capillary tube
[3.0 o [1.4 o 500o2
Capillary tube
[3.0 o [1.8 o 200
Refrigerant flow in cooling
Refrigerant flow in heating
Liquid
[6.35(1/4)
11m
12m
13m
200
250
300
Calculation : Xg=50g/mx(A-7)m
E3
Defrost
thermistor
RT61
14m
15m
350
400