Mitsubishi Electric MCFH-13NV-E3 Service Manual page 36

Floor and ceiling type air conditioners
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the indoor heat exchanger.
(1) Remove the grill. (Refer to 1(1) (2))
(2) Remove the screws on both side and in front of the front
panel. (Photo 5)
(3) Remove the screws of the nozzle assembly. (Photo 6)
(4) Remove the electronic box. (Refer to 1)
(5) Remove the indoor fan motor. (Refer to 2)
(6) Remove the screws of the motor support.
(7) Remove the fan casing. (Iower)
(8) Remove the installations of the drain pan and remove the
screws. (Photo 7)
(9) Remove the screws under the drain pan.(Photo 8)
( 10 ) Remove the drain pan.
( 11 ) Remove the indoor heat exchanger.
Photo 5
Screws of
the front
panel
Photo 6
Photo 7
Photo 8
36
PHOTOS
the nozzle
Installations and screws
Screws under
the drain pan
Screws of
assembly