Icom IC-706MKIIG Service Manual page 20

Hf/vhf/uhf all mode transceiver
Hide thumbs Also See for IC-706MKIIG:
Table of Contents

Advertisement

TRANSMITTER ADJUSTMENTS (continued)
ADJUSTMENT
ADJUSTMENT CONDITION
1
• Display frequency: 14.10000 MHz
IDLING
• Mode
CURRENT
• [Q2 MIC GAIN]
(for drive
• turn R162, R174, R175, R214,
amplifiers)
R231 (on the PA unit) to maximum
counterclockwise position.
• Disconnect the plug from J571 on
the PA unit.
• Transmitting
2
• Display frequency: 145.10000 MHz
• Mode
• [Q2 MIC GAIN]
• Transmitting
(for final
3
• Display frequency: 14.10000 MHz
amplifiers)
• Mode
• [Q2 MIC GAIN]
• Transmitting
4
• Transmitting
5
• Display frequency: 145.10000 MHz
• Mode
• [Q2 MIC GAIN]
• Transmitting
SWR
• Display frequency: 14.10000 MHz
1
DETECTION
• Mode
• Ground CP1071 on the MAIN board.
• Connect an audio generator to
[MIC] connector and set as:
1.5 kHz/30 mV
• Transmitting
• Transmitting
2
3
After remove the jumper wire from CP1071 on the MAIN board.
MEASUREMENT
UNIT
PA
Connect
: USB
ammeter
: 1 (minimum)
the DC power supply
and transceiver's DC
power socket (P601
on the PA unit).
: USB
: 1 (minimum)
: USB
: 1 (minimum)
: USB
: 1 (minimum)
Rear
Connect
: USB
Panel
power
[ANT1] connector.
FILTER
Connect
multimeter to check
point W16.
4 - 6
VALUE
LOCATION
a
DC
0.5 A increase from that
between
R162 is in maximum
counterclockwise posi-
tion.
1.0 A increase from
step 1.
1.0 A increase from that
R174 is in maximum
counterclockwise posi-
tion.
1.0 A increase from
step 3.
2.0 A increase from
step 4.
an
RF
100 W
meter
to
a
digital
Minimum voltage
ADJUSTMENT
POINT
UNIT
ADJUST
PA
R162
R214
R174
R175
R231
Quick
Q2 MIC
set
GAIN
mode
FILTER
C58

Hide quick links: