Page 16

SELECT LOCATION

The first step in installing the equipment is to
select the location. The purchaser of the unit will
have a desired spot in mind, check out that spot
to insure that it is:
- indoors, in an environment that does not exceed
the air and water temperature limitations for the
equipment.
- that the necessary utilities are available including
the correct voltage electrical power.
- that there be space around the installed machine
for service, 15 cm. minimum left, right, and rear
for air-cooled models.

STORAGE BIN

The Scotsman bins for these units are the B 193
and B 393. Other bins may be available with bin
tops to vary the storage capacity. Lay the bin on
its back, using cardboard from the carton to
support it, screw in the legs.
Stand the bin upright, and correct any possible
small tears in the machine mounting gasket with
food grade silicone sealant.

ICE MACHINE

The use of a mechanical lift is recommended for
lifting the uncrated icemaker onto the bin.
Remove front, top and sides panels.
Place the unit directly onto the bin, align it with
the back of the bin. Locate the hardware package,
take out two mounting screws, and use them to
secure the Icemaker to the two sides of the bin.
See illustration below.
Remove all shipping material as well as the masking
tapes from the ice deflector/evaporator cover.
Remove first the ice deflector/evaporator cover
then the masking tape from the ice thickness
sensor.
AIR BAFFLE
Install on the back side of the machine the air
baffle as per instruction provided with it.
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
WATER INLET
AIR-COOLED MODELS: The recommended
water supply is cold water connected to
the - 3/4'' gas - male fitting at the back of the
cabinet. Install a hand valve near the machine to
control the water supply.
1) Switch
2) Plug receptacle
3) Electrical plug
4) Water inlet
5) Shut-off valve
6) Water filter
Page 16
7) Water outlet line
8) Bin water outlet line
9) Open vented water drain
10) Water outlet from the
condenser: water cooled
version only.