SERVICE MANUAL
MVP 456
MVP 606
MVP 806
MVP 1006
SCOTSMAN EUROPE - FRIMONT SPA
Via Puccini, 22 - 20010 Pogliano M.se - Milano - Italy
Tel. +39-02-93960.1 (Aut. Sel.)- Telefax +39-02-93550500
Direct Line to Service & Parts:
Phone +39-02-93960350 - Fax +39-02-93540449
Website: www.scotsman-ice.com
E-Mail: scotsman.europe@frimont.it
Page 1
REV. 10/2008

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman MVP456

  • Page 1 MVP 456 MVP 606 MVP 806 MVP 1006 SCOTSMAN EUROPE - FRIMONT SPA Via Puccini, 22 - 20010 Pogliano M.se - Milano - Italy Tel. +39-02-93960.1 (Aut. Sel.)- Telefax +39-02-93550500 Direct Line to Service & Parts: Phone +39-02-93960350 - Fax +39-02-93540449 Website: www.scotsman-ice.com...
  • Page 2: Table Of Contents

    Page 2 Page 2 INTRODUCTION This technical manual covers the New Prodigy MVP line. All models are shipped with an Installation and User’s manual, which can be referred to separately. General installation information is included in this manual. Page TABLE OF 3 ÷10 CONTENTS Specifications...
  • Page 3 Page 3 Page 3 SPECIFICATIONS MODULAR CUBER MVP 456 ice making capacity AIR COOLED MODELS WATER COOLED MODELS °C °C K g . K g . °C °C WATER TEMPERATURE WATER TEMPERATURE NOTE. To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on last pages of this manual.
  • Page 4 Page 4 Page 4 SPECIFICATIONS (CONT'D) Dimensions: HEIGHT 575 mm. (22" 1/2) WIDTH 760 mm. (30") DEPTH 620 mm. (24" 1/2) WEIGHT 77 Kgs. MVP 456 - MACHINE SPECIFICATIONS Water req. Model Cond. unit Finish Comp. HP lt/24 HR MVP 456 - AS 410* Stainless Steel MVP 456 - WS...
  • Page 5: Specifications

    Page 5 Page 5 SPECIFICATIONS MODULAR CUBER MVP 606 ice making capacity AIR COOLED MODELS WATER COOLED MODELS °C °C K g . K g . °C °C WATER TEMPERATURE WATER TEMPERATURE NOTE. To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on last pages of this manual.
  • Page 6 Page 6 Page 6 SPECIFICATIONS (CONT'D) Dimensions: HEIGHT 575 mm. (22" 1/2) WIDTH 760 mm. (30") DEPTH 620 mm. (24" 1/2) WEIGHT 77 Kgs. MVP 606 - MACHINE SPECIFICATIONS Water req. Model Cond. unit Finish Comp. HP lt/24 HR MVP 606 - AS 440* Stainless Steel 1 3/8...
  • Page 7 Page 7 Page 7 SPECIFICATIONS MODULAR CUBER MVP 806 ice making capacity AIR COOLED MODELS WATER COOLED MODELS °C °C K g . K g . °C °C WATER TEMPERATURE WATER TEMPERATURE NOTE. To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on the last pages of this manual.
  • Page 8 Page 8 Page 8 SPECIFICATIONS (CONT'D) Dimensions: HEIGHT 725 mm. (28" 1/2) WIDTH 760 mm. (30") DEPTH 620 mm. (24" 1/2) WEIGHT 97 Kgs. MVP 806 - MACHINE SPECIFICATIONS Water req. Model Cond. unit Finish Comp. HP lt/24 HR MVP 806 - AS 580* Stainless Steel 1 5/8...
  • Page 9 Page 9 Page 9 SPECIFICATIONS MODULAR CUBER MVP 1006 ice making capacity AIR COOLED MODELS WATER COOLED MODELS °C °C K g . K g . °C °C WATER TEMPERATURE WATER TEMPERATURE NOTE. To keep your Modular cuber performing at its maximum capacity, it is necessary to perform periodic maintenance as outlined on the last pages of this manual.
  • Page 10 Page 10 Page 10 SPECIFICATIONS (CONT'D) Dimensions: HEIGHT 725 mm. (28" 1/2) WIDTH 760 mm. (30") DEPTH 620 mm. (24" 1/2) WEIGHT 104 Kgs. MVP 1006 - MACHINE SPECIFICATIONS Water req. Model Cond. unit Finish Comp. HP lt/24 HR MVP 1006 - AS 600* Stainless Steel MVP 1006 - WS...
  • Page 11: Water

    Page 11 Page 11 WATER GENERAL INSTALLATION Air or Water Cooled The quality of the water supplied to the ice machine will have an impact on the time between Location Limitations: cleanings and ultimately on the life of the product. There are two ways water can contain impurities: The product is designed to be installed indoors, in suspension or in solution.
  • Page 12 Page 12 Page 12 Water Filters Horizontal runs of drain tubing need a 1/4" fall per foot of run for proper draining. If connecting to water filtration, filter only the water to the reservoir, not to the condenser. Follow all applicable codes. Install a new cartridge if the filters were used with a prior machine.
  • Page 13: Adjustments

    Page 13 Page 13 ADJUSTMENTS Ice Bridge Thickness Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments are not covered by warranty. Shut machine off. Access the ice thickness sensor. Check gap between metal tip and evaporator grid.
  • Page 14: Prodigy Cuber System Information

    Page 14 Page 14 Code Display PRODIGY CUBER SYSTEM Main codes - automatically displayed INFORMATION Freeze Cycle F flashes Freeze Cycle is Pending Overall System Type: Harvest Cycle H flashes Manual Harvest • Refrigeration: Mechanical, either air cooled, Binis Full water cooled.
  • Page 15: How It Works

    Page 15 Page 15 HOW IT WORKS - AIR COOLED uncovered and continues to fill until the top probe is in contact with water. When the reservoir has filled, the compressor and water pump start. Freeze Cycle. At start up the controller drains After the discharge pressure has increased past and refills the reservoir.
  • Page 16: Electrical Component Details

    Page 16 Page 16 The harvest assist solenoid is connected in The display will begin to blink F. The component parallel with the hot gas valve. Although it is indicator lights will switch on and off to match energized throughout the harvest cycle, its piston the following process: does not move until the ice has become partially loosened from the evaporator plate by the action...
  • Page 17 Page 17 Page 17 Harvest Assist Solenoid water contacts a probe suspended over ice • Operated by the controller in parallel with the plate. Signals ready for harvest. hot gas valve. Cycles on and off at the beginning of a restart. Energized throughout the harvest Curtain Switch cycle.
  • Page 18: Refrigeration

    Page 18 Page 18 REFRIGERATION WATER SYSTEM Refrigerant: R-404A Batch type. Water reservoir contains full water charge for each ice making cycle. Compressors: Copeland or Tecumseh hermetic by model Water valve: Solenoid type. Opens to fill reservoir when mid sensor probe no longer makes a circuit Expansion valves: Non adjustable, internally to the bottom probe.
  • Page 19: Control Operation

    Page 19 Page 19 CONTROL OPERATION Min freeze time - 6 minutes If the controller switches the machine into harvest Standard control: within 20 seconds of the minimum freeze time, • Electronic controller operating from a 12 AC volt the controller will harvest for a preset time and power supply.
  • Page 20: Control Button Use (From Standby)

    Page 20 Page 20 CONTROL BUTTON USE (from standby) Test Mode: See next page for Air and Water Cooled mode. Set purge level, 1-5 (1 is minimum, 5 is maximum) • Hold off button in till a number or the letter A or Automatic: shows on display and green STATUS led ON, •...
  • Page 21: Service Specification

    Page 21 Page 21 OPERATING CHARACTERISTICS SERVICE SPECIFICATION On air-cooled models during the freezing cycle, the discharge pressure is maintained between In servicing a machine, it is often, useful to two preset values by means of fan control compare that individual units operating (condenser sensor);...
  • Page 22: Diagnostics - Air Cooled

    Page 22 Page 22 DIAGNOSIS No ice Problem Likely Cause Probable Solution No power to unit Power disconnected Check breaker or fuse. Reset or replace, restart and check No power to controller Transformer open Replace transformer Shut down on maximum Water shut off Restore water supply water fill time...
  • Page 23 Page 23 Page 23 DIAGNOSIS Problem Likely Cause Probable Solution Shut down on maximum Ice bridge thickness too small, Check and adjust if needed harvest time not enough ice to open curtain Ice bridge thickness too large, Check and adjust if needed ice frozen to evaporator frame Purge valve does not open, water Check purge valve...
  • Page 24: Test Procedures - Sensors

    Page 24 Page 24 TEST PROCEDURES ICE THICKNESS SENSOR All electrical components in this ice machine can Test using the controller’s indicator light. be diagnosed with a volt-ohmmeter. Observe the Ready To Harvest light. Shut the machine off. Use a wire to connect the metal part Curtain Switch: of the Ice Thickness sensor to the evaporator or Test using the controller’s indicator lights.
  • Page 25: Temperature Sensors

    Page 25 Page 25 remove it from the sump cover. Test 1: Place one temperature. Any reading within 1000 ohms is lead of the ohmmeter on the longest probe and acceptable. Discharge sensor: Measure the tem- the other on the controller end of the red wire, perature of the discharge line as close to the there should be continuity.
  • Page 26 Page 26 Page 26 Check starting components. Potential relay. If the compressor will not start, check the amp draw of the starting circuit. If very low, the potential relay contacts or start capacitor may be open. Measure the resistance of the potential relay contacts and the start capacitor.
  • Page 27 Page 27 Page 27 Pressure switches four minutes. Push and release the On button to restart the machine. As the unit drains the There are two pressure switches: Fan and High reservoir, the purge valve connection should Pressure cut out. receive full voltage.
  • Page 28: Controller Differences

    Page 28 Page 28 will be ON. If the water valve does not open to fill Hot Gas Valve the reservoir when its indicator light is on, do a Test using the controller’s indicator lights. If voltage check. Shut the unit down by holding the the unit is running, or has been off for more than Off button in for 3 seconds.
  • Page 29: Wiring Diagrams

    Page 29 Page 29 MVP 456/606/806/1006 - WIRING DIAGRAM 220 V. 50 Hz. 1 ph. m = brown bc = light blue gv = yellow green b = white n = black = red a = orange v = viola - Input terminal board - Automatic reset switch - Water pump...
  • Page 30 Page 30 Page 30 MV 1006 - WIRING DIAGRAM 400 V. 50 Hz. 3 ph. m = brown bc = light blue gv = yellow green b = white n = black = red a = orange v = viola K - Automatic reset switch A - Input terminal board L - Water pump...
  • Page 31: Repair Procedures

    Page 31 Page 31 REPAIR PROCEDURES 8 Rotate selector switch to the proper model number for the machine the controller is Ice thickness sensor being installed on. 1 Push and release the Off switch. 2 Remove front and top panels. 3 Push and release the Harvest switch 4 Disconnect electrical power.
  • Page 32: Cleaning, Sanitation And Maintenance

    C . The machine will drain the reservoir and refill it. Go onto the next step when the reservoir has filled. Pour 8 ounces of Scotsman Cleaner 1 ice machine scale remover into the reservoir. Allow the ice machine scale remover to circulate in the water system for at least 10 minutes.
  • Page 33 Remove and discard all ice. metal surfaces of sensor with ice machine scale remover solution. Mix a solution of 7 ounces of Scotsman Clear 1 ice machine scale remover in 84 ounces 16. Mix a solution of sanitizer. of potable water and wash all interior surfaces of...

This manual is also suitable for:

Mvp606Mvp806Mvp1006