Benchmark Buderus 600-28C User Manual

Benchmark Buderus 600-28C User Manual

Gas wall hung boiler condensing

Advertisement

7212 8000 - 02/2006 GB/IE (EN)

Users manual

Gas wall hung Boiler condensing
Buderus 600 - 28C
Please read thoroughly before operating the unit
For the user

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Buderus 600-28C and is the answer not in the manual?

Questions and answers

Summary of Contents for Benchmark Buderus 600-28C

  • Page 1: Users Manual

    7212 8000 - 02/2006 GB/IE (EN) For the user Users manual Gas wall hung Boiler condensing Buderus 600 - 28C Please read thoroughly before operating the unit...
  • Page 2 Preface Introduction Please read these instructions and follow them carefully for a safe and economical use of your boiler. Important general instructions for use This device should only be used for its intended purpose and in accordance with the operating instructions. It is the law and in your own interest, and that of safety that this boiler must be installed by a CORGI registered installer, in accordance with the relevant requirements of...
  • Page 3: Safety Precautions

    Users manual Working in the heating Dear Customer, system Your Buderus 600 Series wall-mounted condensing gas boiler has been designed and built in accordance with state-of-the-art technological standards and the DANGER ! recognised safety rules. Special focus has been placed Only a CORGI registered Engineer is to be on operator convenience in this respect.
  • Page 4: Preparing For Operation

    Users manual Initial start-up Preparing for operation Please note also the operating instructions supplied with the control unit. 6.1.1 Check water pressure Open the control panel cover (fig. 1). Press the service button until the system pressure "P1.1" appears in the display. Optimum filling pressure is 1.5 bar.
  • Page 5 Users manual Connect temporary hose (fig. 4). Open both stop valves. stop stop valve valve double check valve temporary hose cold return Fig. 4 Temporary hose Fill the system to a pressure of approx. 1.5 bar (fig. 5, item 2). Shut both stop valves and disconnect the filling loop.
  • Page 6: Operational And Fault Codes

    Users manual Frost hazard for the heating system NOTE Normally set by commisioning Engineer. Press the chimney sweep button and the service button (see fig. 6, item 2 and 3) simultaneously until "L--" appears in the display. Press the service button repeatedly until for example “F 5”...
  • Page 7: Draining The System

    Users manual Taking the system out of service Open the control panel cover (see fig. 1). Push the mains power switch (fig. 7, item 1) to “0”. Close the gas service valve by turning it clockwise (fig. 8, item 1). Close the control panel cover (fig.
  • Page 8 Heating system specialist: Buderus Cotswold Way Warndon Worcester WR4 9SW Telephone: 01905 - 752 936 Fax: 01905 - 753 130 Customer Services: Tel: 0870 - 421 5933 Technical Product Support: Tel: 0870 - 421 5944 Sales: Tel: 01905 - 752 640 Fax: 01905 - 456 445 / 455 394 Returns: Tel: 01905 - 752 531...