S-Access SA-PAM-SAN-ETH User Manual

G.shdsl modem

Advertisement

Quick Links

SA-PAM-SAN-ETH
SA-PAM-SAN-ETH-ROHS
SA-PAM-SAN-ETH,4W
SA-PAM-SAN-ETH/FXO
SA-PAM-SAN-ETH/FXS
SA-PAM-SRL-ETH
SA-PAM-SRL-ETH,4W
SA-PAM-SRL-ETH/FXO
SA-PAM-SRL-ETH/FXS
G.SHDSL Modem
USER MANUAL
Version
Revision
Document name
User Manual
2.0
18 September 2005
_SAUM_PAM-SAN-Eth_v2-0-070201.doc

Advertisement

Table of Contents
loading

Summary of Contents for S-Access SA-PAM-SAN-ETH

  • Page 1 User Manual SA-PAM-SAN-ETH SA-PAM-SAN-ETH-ROHS SA-PAM-SAN-ETH,4W SA-PAM-SAN-ETH/FXO SA-PAM-SAN-ETH/FXS SA-PAM-SRL-ETH SA-PAM-SRL-ETH,4W SA-PAM-SRL-ETH/FXO SA-PAM-SRL-ETH/FXS G.SHDSL Modem USER MANUAL Version Revision 18 September 2005 Document name _SAUM_PAM-SAN-Eth_v2-0-070201.doc...
  • Page 2 SA-PAM-SAN-Eth User Manual © Copyright © 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of S- Access GmbH.
  • Page 3: Table Of Contents

    SA-PAM-SAN-Eth User Manual VERSION CONTROL ....................5 GENERAL INFORMATION ..................7 ORDER INFORMATION.................... 8 DESCRIPTION OF THE DEVICE ................9 Exterior design SAN models................9 LED STATUS....................9 Back panel ...................... 11 Exterior design SRL models ................12 RULES OF SWITCHING ..................14 The SAN (Stand alone) delivery set ...............
  • Page 4 SA-PAM-SAN-Eth User Manual SNMP........................26 Traps....................... 26 TECHNICAL SPECIFICATIONS ................27 STORAGE CONDITIONS..................28 CONNECTOR’S DESCRIPTION ................29 11.1 DSL Connector ....................29 11.2 DSL Connector for SRL units ................. 29 11.3 Monitor Connector ..................30 11.4 PC and Hub Connectors................. 30 11.5 Line1 and Line2 Connector................
  • Page 5: Version Control

    SA-PAM-SAN-Eth User Manual 1 VERSION CONTROL Version Date Major changes to previous version 31.12.2001 Initial version of the manual corresponding to version 1.2 of the device micro program 23.10.2003 New function description corresponding to software release V1.6 Corrected Connecter description 9.1 Changed DSL cable to twisted type 10.2...
  • Page 6 SA-PAM-SAN-Eth User Manual EU Directive 2002/96/EC and EN50419 This equipment is marked with the above recycling symbol. It means that at the end of the life of the equipment you must dispose of it separately at an appropriate collection point and not place it in the normal domestic unsorted waste stream.
  • Page 7: General Information

    Telnet port for the local / remote management • SNMP Management • Remote TFTP Software upload • 230 Vac power For SA-PAM-SAN-Eth/FXO/FXS • up to 2 voice cannel. S-Access GmbH Tel: +41 44 700 31 11 Oberhausenstrasse 47 Fax: +41 44 700 31 03...
  • Page 8: Order Information

    SA-PAM-SRL-Eth Modem S-Access Discovery, SubRack, G.shdsl, 10/100Base- T Bridge, VLAN, Adapter 230 Vac SA-PAM-SAN-Eth,4W Modem S-Access Discovery, Tabletop, G.shdsl, 2 pairs, up to 4.6Mbps, 10/100Base-T Bridge, VLAN, Adapter 230 Vac SA-PAM-SRL-Eth,4W Modem S-Access Discovery, SubRack, G.shdsl, 2 pairs, up to 4.6Mbps, 10/100Base-T Bridge, VLAN, Adapter 230 Vac...
  • Page 9: Description Of The Device

    SA-PAM-SAN-Eth User Manual 4 DESCRIPTION OF THE DEVICE 4.1 Exterior design SAN models The front panel of the device has 3 LEDs (FXO and FXS has 2 additional LEDs): 4.2 LED STATUS LOCAL informs the user about the status of the local device. The following four statuses are possible «blinking red»...
  • Page 10 SA-PAM-SAN-Eth User Manual «green» Ethernet link established PORT1 If the unit is a FXO or FXS model then the LED indicates the following status of Line2: «off» Telephone line inactive «red» Telephone line active (FXO unit) «green» Telephone line active (FXS unit)
  • Page 11: Back Panel

    “HUB” connector to connect the modem to the LAN using a straight Patch Cord; • the “DSL” connector to connect the modem to the leased physical line. The back panel of the SA-PAM-SAN-Eth modem has additionally: • “PC” connector to connect the modem to the LAN using a straight Patch Cord;...
  • Page 12: Exterior Design Srl Models

    SA-PAM-SAN-Eth User Manual 4.4 Exterior design SRL models S-Access GmbH Tel: +41 44 700 31 11 Oberhausenstrasse 47 Fax: +41 44 700 31 03 Page 8907 Wettswil a/A Email: contact@s-access.ch Switzerland WEB: www.s-access.ch...
  • Page 13 SA-PAM-SAN-Eth User Manual Status(L) informs the user about the status of the local device. The following four statuses are possible «blinking red» informs the user about malfunctioning of the modem’s hardware and software. In this case, the modem is out of order and should be submitted to the service center for being repaired.
  • Page 14: Rules Of Switching

    SA-PAM-SAN-Eth User Manual 5 RULES OF SWITCHING 5.1 The SAN (Stand alone) delivery set The delivery set includes: • the subscriber access device (a modem) • the power supply source (an AC adapter) • the cables for the line connections 5.2 The SRL (SubRackCard) delivery set...
  • Page 15 SA-PAM-SAN-Eth User Manual To update the information on the screen use the “Enter” key. The following menu will appear on the screen. Input Password: Please enter your programmed password. The unit will be delivered without a password, if there is a password: default password “admin”...
  • Page 16: The Command System

    SA-PAM-SAN-Eth User Manual 6 THE COMMAND SYSTEM 6.1 Basic rules After the command is typed, press <enter>. The <Backspace> key is used to edit commands. It is necessary to input item number, for choosing menu item, You can use “PageUP”, “PageDown” and “Space” keys, for scrolling list of available value of parameters, The “Esc”...
  • Page 17: Performance Management Submenu

    SA-PAM-SAN-Eth User Manual 6.3 Performance management submenu Upon activation of the performance management submenu the following message will be displayed. Performance Management 1.Loop Status... 4.EtherNet Status... 7.HDLC Status... Select item number or ESC to Upper level menu>> 6.3.1 Loop Status submenu Upon activation of the performance management submenu the following message will be displayed.
  • Page 18: Ethernet Status Submenu

    SA-PAM-SAN-Eth User Manual 6.3.2 Ethernet Status submenu Upon activation of the performance management submenu the following message will be displayed. Performance Management->EtherNet Status Link:Link down Link Speed:---- Link Duplex:---- Used Entries:0 Tx Packets:0 Rx Packets:0 Fwd Packets:0 Drop Packets:0 Speed:Auto...
  • Page 19: Hdlc Status Submenu

    SA-PAM-SAN-Eth User Manual 6.3.3 HDLC Status submenu This menu contains statistical information about the HDLC packets that are sent between master and slave. Perfomance Managment->HDLC Status Channel_A Channel_B HDLC Tx Cnt:0 HDLC Tx Cnt:0 HDLC Rx Cnt:0 HDLC Rx Cnt:0...
  • Page 20: Dsl Setup

    SA-PAM-SAN-Eth User Manual 6.4.1 DSL Setup In this menu you can setup the DSL link. When you have selected that menu, the following will appear: Configuration Management->DSL Setup 1.[Loop 1 Operation Mode]:Slave 2.[Loop 1 Auto/Fixed]:Fixed 5.[Loop 1 Fixed Connection Speed]:2312K(36N) 6.[Loop 1 Annex]:A/B...
  • Page 21 SA-PAM-SAN-Eth User Manual 6.4.1.3 Min- Max Connection Speed (only if Auto selected and FW 2.41 for 4W) • In the Min. Max Connection Speed menu, you can specify your desired Adaptive mode speed limit borders in the range of 72 kbps to 2312 kbps for 2wire units and 528 kbps to 4624 kbps for 4wire models.
  • Page 22 SA-PAM-SAN-Eth User Manual 6.4.1.8 Reserve mode 1+1 The characteristic property of reserve mode 1+1 is data multiplexing on the every from xDSL interfaces, and as a result, connection between modems will be broken partially when broken one pair. In other words common capacity decrease and some channel intervals (which are located in cross-connect table) don’t translate.
  • Page 23: Ethernet Setup Submenu

    SA-PAM-SAN-Eth User Manual 6.4.2 Ethernet Setup submenu Configuration Management->EtherNet Setup 1.[Speed]:Auto 2.[Duplex Mode]:Auto 3.[Disable Mac Filter]:No 4.IP Address>>192.168.5.105 5.Subnet Mask>>255.255.255.0 6.Gateway Address>>192.168.5.1 8.NMS IP Address>>192.168.5.32 9.Read Community>> 10.Write Community>> 11.Trap Community>> 12.[Enable TFTP Server]:Yes 13.[DSL Reboot]:No 14.[Time before Reboot]:1min 15.[Management VLAN]:No 16.VLAN ID>>2222...
  • Page 24: Profile Submenu

    SA-PAM-SAN-Eth User Manual • [Trap Community] Password which will be set in each event, sending to SNMP management system. This password are using for identification of messages from a guided units. Maximum length – 10 symbols • [Enable TFTP Server]: Permission/prohibition remote upgrade SW of the modem. TFTP access has poor protection.
  • Page 25: Tftp Upload

    SA-PAM-SAN-Eth User Manual 7 TFTP UPLOAD 7.1 Unit preparation Its suggested to connect the PC Terminal to the monitor connector for the observation of the download procedure. • Enter the Ethernet Setup submenu. • Enter menu point [Enable TFTP Server] and switch TFTP on •...
  • Page 26: Snmp

    SA-PAM-SAN-Eth User Manual 8 SNMP 8.1 Traps The unit supports the following traps: Trap Description Cold start Sent on unit startup Linkup Sent on DSL link up Linkdown Sent on DSL link loss Authorization Error Sent on reception of a wrong community string (hacker attack)
  • Page 27: Technical Specifications

    SA-PAM-SAN-Eth User Manual 9 TECHNICAL SPECIFICATIONS The main technical specifications of modems of the S-Access family are presented below in the table. Line interface. Standard ETSI 101 135 Regulation -RoHS = RoHS ready (Pb-free) Number of pairs 1 or 2...
  • Page 28: Storage Conditions

    С. The equipment can also withstand air-transport at a low air pressure of 12 о kPa (90 Torr) at -50 С. The packed equipment of the S-Access family can be stored within 12 months (from the date of transshipment including transporting...
  • Page 29: Connector's Description

    SA-PAM-SAN-Eth User Manual 11 CONNECTOR’S DESCRIPTION 11.1 DSL Connector Type: RJ-45, 8 pin Number Signal Assignment RJ-45 LB,a tip (4W model only) LA,a LA,b ring LB,b ring (4W model only) 11.2 DSL Connector for SRL units Type: RJ-45, 8 pin...
  • Page 30: Monitor Connector

    SA-PAM-SAN-Eth User Manual 11.3 Monitor Connector Type: Sub-D9, female Number Signal Assignment Transmit data Receive data Data terminal ready SGND Signal ground female 11.4 PC and Hub Connectors Type: RJ-45 Number PC assignment HUB assignment RJ-45 S-Access GmbH Tel: +41 44 700 31 11...
  • Page 31: Line1 And Line2 Connector

    SA-PAM-SAN-Eth User Manual 11.5 Line1 and Line2 Connector Type: RJ-11, 4 pin Number Signal Assignment RJ-11 LA,a LA,b ring S-Access GmbH Tel: +41 44 700 31 11 Oberhausenstrasse 47 Fax: +41 44 700 31 03 Page 8907 Wettswil a/A Email: contact@s-access.ch...
  • Page 32: Description Of Interface Cables

    SA-PAM-SAN-Eth User Manual 12 DESCRIPTION OF INTERFACE CABLES 12.1 Ethernet cable Side А Color of wire Side B white/green green/white white/orange blue/white white/blue orange/white white/brown. brown/white 12.2 DSL cable Side А Color of wire Side B white/green green/white white/orange blue/white...

Table of Contents