Before Each Heating Season; Fan Wiring Diagrams - Masport HORIZON Owner's Manual & Installation Manual

Hide thumbs Also See for HORIZON:
Table of Contents

Advertisement

FAN MAINTENANCE
Only the manufacturer, its service agent or a similarly qualified person should remove the
bottom grille of the Grande Provincial or the ash shelf of the LE 7000 Provincial to carry out
fan installation, servicing and maintenance. The fan should need little attention other than
occasionally removing it to clean dust and lint from the impeller. First unplug the mains lead from the
power point. Fans on in-built fires can be accessed by lifting off the ash shelf. Fans on free-standing
fires are reached by removing the rear of the pedestal. On free-standing models with internally
switched fans, first gently ease off the speed control knob, taking care to pull it off squarely. Remove
the four screws (two on the Grandview) which hold the fan box in position.
If the fan on the free-stander is internally switched, move it slightly away from the switch end and
withdraw it completely. Some fans simply stand on rubber bushes fitted over fixed posts. These
simply lift away vertically from the post (remove any shipping nuts first, but do not replace it). Clean
the impeller blades carefully by blowing or vacuuming, and reassemble in the reverse order.
CLEANING THE FLUE
This may be needed about once a year or more frequently under adverse conditions. Signs of creosote
and soot build-up are inadequate draught, smoking when the door is opened and a dull thud when the
outside of the flue is tapped. A blocked flue can be cleaned only by sweeping. DO NOT USE
CHEMICAL CHIMNEY CLEANERS.
FLUE INSPECTION
Check regularly that the flue is sound, particularly the metal base of enamelled flues.

BEFORE EACH HEATING SEASON.

To ensure continued safety, check the condition of the following items; the flue system (particularly
the flue sections nearest the firebox), the firebox top baffle, the firebox liners (bricks and boards) and
the door gasket. Replace parts only with genuine MASPORT spares.
MAINS LEAD
MAINS LEAD
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
________________________________________________

FAN WIRING DIAGRAMS

CONNECTORS
BROWN
BRN
BLUE
BLUE
GN/YEL
SWITCH LOOM
588068
LE 7000 PROVINCIAL FAN WIRING DIAGRAM — TWO SPEED
CONNECTORS
BROWN
BRN
BLUE
BLUE
GN/YEL
SWITCH LOOM
588068
GRANDE PROVINCIAL FAN WIRING DIAGRAM — TWO SPEED
similarly qualified person in order to avoid electrical hazard.
SIX PIN PLUG AND SOCKET
ORANGE
RED
GN/YEL
EARTH POST
590226
SIX PIN PLUG AND SOCKET
ORANGE
ORANGE
RED
RED
BLUE
GN/YEL
GN/YEL
EARTH POST
EXTENSION
LOOM
590226
595197
17
SWITCH
BROWN
BLACK
BLUE
GN/YEL
FAN
595652
SWITCH
BROWN
BLACK
BLUE
GN/YEL
FAN
595652
FAN
595199
FAN
595198