MBM150 (BOWDEN MINI) Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA. MBMS150 (BOWDEN MINISTACKER) VERSION 1.1...
1.1. AIR CONTROLS USER INSTRUCTIONS The Masport Bowden range of wood heaters feature a single air control system. It is designed to introduce oxygen into the base of the fire, controlling the rate of INTRODUCTION combustion of the wood. In addition, oxygen is drawn into the upper firebox where combustion of the gases occurs.
USING THE APPLIANCE FOR THE fire establishes and the glass warms to avoid the build-up of condensation. FIRST TIME The first few times the appliance is lit, it will give off some Add larger pieces of wood. Too many logs may odorous fumes.
5.3. RELOAD WITH MORE WOOD 6.2. FLUE DRAUGHT Open air slide before opening door. The flue has two main functions: Rake / break up any existing coals. To safely remove smoke, gases and fumes from the appliance. Load the wood with the length oriented front to back.
ASH REMOVAL CLEANING THE FLUE Depending on the type of wood burnt and frequency, the Check inside of flue prior to each season for any build-up ashes will need removing every 2 to 6 weeks. of creosote (wood tar). To do this: Retaining a minimum of 10mm of ash helps protect the First remove the baffle (refer to “2.
TROUBLESHOOTING TIPS 11.1. GLASS IN DOOR BLACKENING This can have several possible causes: • Burning unseasoned wood — if the wood is too wet, it will cause the glass to blacken. • Appliance operated at low temperature — after an overnight burn where the air slide control has been fully closed, the glass may have blackened.
To remove/install the baffle: MAINTENANCE AND SERVICING Remove the brick retainers and bricks. Remove the front baffle retainer. REPLACEMENT OF FIRE BRICKS Shift the baffle to the right of the heater, lifting the The purpose of the firebricks in the appliance is to baffle up on the right side.
REMOVING THE DOOR ADJUSTING THE DOOR LATCH To remove the door: Over time, the door seal can become compressed, resulting in a less than adequate seal between the door Open the door all the way. and the front edge of the firebox. For example, if the wood burns unusually fast even with the air slide shut, it Lift the door up and over the top end of the vertical may mean that there is an air leak around the door.
To replace the door glass: LATCH BUSHING LATCH BUSHING 12.5MM OD 10MM OD BARREL NUT LATCH NUT Place the door glass side down on a work-bench. LATCH BOLT Remove the 8x M6 nuts securing the glass retainers. Carefully turn the door over so the frame is resting FITTING A NEW DOOR SEAL on the bench.
REPLACEMENT SPARE PARTS LIST PART NO. PART DETAIL N900-319 Fire Brick Set 4 @ 220 x 175 x 25mm 3 @ 220 x 85 x 25mm Brick Retainers 3 X Stainless brick retainer straight, 2 X corner (included in brick set) N501-078 Baffle Plate Kit 403 x 240 x 25mm vermiculite, matching front retainer...
The Wood Fire is not installed in accordance with This warranty is provided to the first domestic purchaser AS/NZS 2918 or any building code or consent; of a Masport wood fire (radiant or convection). It applies from the date of purchase from or through an authorized •...
Page 15
• Direct, indirect or consequential losses or special damages of any kind (including costs of collection and delivery) other than repair or replacement of products or components under this warranty, where any goods are acquired or used for the purposes of a business; How to obtain warranty service? •...
Page 16
Glen Dimplex Australia Pty Ltd 8 Lakeview Drive, Scoresby Victoria 3179 Australia T: 1300 556 816 | F: 1800 058 900 General and Sales Enquiries: flame@glendimplex.com.au Technical Service: service@glendimplex.com.au www.glendimplex.com.au...