Fuel Valve Maintenance; Engine Maintenance - Briggs & Stratton Portable Generator Operator's Manual

Hide thumbs Also See for Portable Generator:
Table of Contents

Advertisement

Available languages

Available languages

Fuel Valve Maintenance

The fuel valve is equipped with a fuel sediment cup, screen,
and o-ring that need to be cleaned.
1. Move fuel valve to "Off" position.
2. Remove sediment cup (A) from fuel valve. Remove
o-ring (B) and screen (C) from fuel valve.
C
B
A
3. Wash sediment cup, o-ring, and screen in a
nonflammable solvent. Dry them thoroughly.
4. Place screen and o-ring into fuel valve. Install sediment
cup and tighten securely.
5. Move fuel valve to "On" position, and check for leaks.
Replace fuel valve if there is any leakage.

Engine Maintenance

WARNING Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF, SG,
SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for
the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.
16
* Below 40°F (4°C) the use of SAE 30 will result in hard starting.
** Above 80°F (27°C) the use of 10W30 may cause increased oil
consumption. Check oil level more frequently.
NOTICE Synthetic oil meeting ILSAC GF-2, API
certification mark and API service symbol with
"SJ/CF ENERGY CONSERVING" or higher, is an
acceptable oil at all temperatures. Use of synthetic
oil does not alter required oil change intervals.
Checking Oil Level
Oil level should be checked prior to each use or at least
every 8 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Clean area around oil fill and remove oil fill cap.
3. Verify oil is at the point of overflowing at oil fill
opening.
4. Replace and tighten oil fill cap.
Adding Engine Oil
1. Make sure generator is on a level surface.
2. Check oil level as described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the
point of overflowing at oil fill.
4. Replace and tighten oil fill cap.
BRIGGSandSTRATTON.COM

Advertisement

Table of Contents
loading

Table of Contents