12-6. Dipswitch settings

The 110 Indoor shares the computer board with the 110
Outdoor. Each dipswitch has a special function shown on
the following table. The gas type and model type should
not need adjustment. Carefully verify the functions of the
dipswitch before changing any settings.
No.
Functions
1
Gas type
2
3
FM+, FM++ and FM+++
4
(FM speed is increased automatically. See section 12-8)
OFF position
No. 4
ON position
5
N/A
6
Model type
7
Output temperature settings
8
(See table to the right)
(Default 122°F)
No. 3
OFF
ON
position
position
0 %
+6 %
+12 %
+ 18 %
50
110 Indoor / 110 Outdoor Service Manual
ON position
Propane
Natural gas
OFF position
No. 4
ON position
N/A
(Default)
110 Outdoor
CONFIDENTIAL
Ver. 1.01
Dipswitches
OFF position
Disable
Disable
No. 3
OFF
ON
position
position
0 %
+4 %
+8 %
+ 12 %
(Default)
(Default)
110 Indoor