Procedures; Verifying Proper Dipswitch Settings - A.O. Smith T-H2S-DV Troubleshooting Manual

Table of Contents

Advertisement

5.4 TROUBLESHOOTING – PROCEDURES 
 
Verifying proper Dipswitch settings  p.22 
Draining the unit 
Cleaning the filter 
Checking for a Cross Connection 
Check for Reverse Connection 
Check gas supply pressure 
Purge the gas line of air 
Adjusting manifold pressure   
Resetting the Computer Board 
Checking the OHCF   
VERIFYING PROPER DIPSWITCH SETTINGS:  
Incorrect Dipswitch settings can cause a 031 
error code. 
 
Table 4 – Left Bank of Dipswitches 
No. 
Allow adjustments of fan motor speed 
(Similar procedure to changing manifold pressure) 
INPUT‐ (Maximum gas input is reduced) 
Allow access to operation history 
10 
Type of water heater model 
 
 
p.23 
 
 
p.23 
p.24 
p.24 
 
p.24 
 
p.24 
p.25 
p.26 
 
p.26 
Function 
Gas type 
N/A 
Fan motor for combustion 
 
No.6 
OFF position 
ON position 
Fan motor for exhaust (Indoor models only) 
  
No.6 
OFF position 
ON position 
(Special purpose only) 
N/A 
Figure 23 
ON position 
Propane 
Natural Gas 
Enable 
FM+, FM++, FM+++ 
No.5 
OFF position 
0% 
+12% 
 
No.5 
OFF position 
0% 
+7.3% 
  
‐10% Max 
Input 
EEPROM data 
transfer 
Indoor 
22|
 Page 
 
Troubleshooting Guide 
OFF position 
Disable 
Disable 
N/A 
N/A 
(Default) 
Disable  
(Default) 
ON position 
+6% 
+18% 
ON position 
+3.6% 
+11.4% 
Disable 
(Default) 
Disable 
(Default) 
N/A 
N/A 
(Default) 
Outdoor 
 