Gas Valve Assembly - A.O. Smith 110 Indoor Service Manual

Direct vent on-demand water heater
Table of Contents

Advertisement

10-4. Gas valve assembly

Unit Part #
Function
Failure events
Effects on the water
heater if valves fails
Error codes when the
valves fails
Diagnostic
Color/Number of wires
Proportional Valve
#102
AOS Part #
Opens and closes the gas pathways of the water heater (main and solenoid
gas valves)
Modulates the gas flow from the gas inlet (proportional gas valve)
1. Gas leak from the valves.
2. Unable to open/close (main and solenoid gas valves)
3. Unable to modulate the gas flow (proportional gas valve)
1. Gas leak from the unit.
2. Excess carbon monoxide emissions. / No flames.
3. Lack of water temperature control.
11
1. Visual inspection: connection/breakage of wires.
2. Listen for "clunk" sounds from the gas valves opening right after fan motor
initiates.
3. Check voltages and resistance of coils; proper range of values shown
below.
Blue - Light blue (MV)
Blue - Green (SV
)
1
Blue - Orange (SV
)
2
Blue - Red (SV
)
3
White –Red
(Proportional valve)
319143-169 (for LP model) and 319143-165 (for NA
model) is an assembly of the gas manifold with gas
valve assembly. For safety reasons, these assemblies
should be installed in the unit as a whole set. The
diagram below shows the gas valve assembly.
110 Indoor / 110 Outdoor Service Manual
319143-169 (LP)
319143-165 (NA)
12
78 to 100 VDC (during operation) / 0.9 to 1.3 kΩ
78 to 100 VDC (during operation) / 1.3 to 1.9 kΩ
78 to 100 VDC(during operation) / 1.3 to 1.9 kΩ
78 to 100 VDC (during operation) / 0.9 to 1.7 kΩ
1.0 to 15 VDC (during operation) / 20 to 40 Ω
20
CONFIDENTIAL
Ver. 1.01
Checkpoint
51
70
C,H1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-kjr2-inT-kjr2-os

Table of Contents