Further details regarding the individual steps

Checking and replacing the magnesium anode (if required)

F
Commissioning, inspection, maintenance
5. Use a chemical cleaning agent to
remove hard deposits that cannot be
removed by a high pressure
cleaner.
!
Please note
Cleaning agents containing
hydrochloric acid attack the
material of the DHW cylinder.
Never use such cleaning
agents.
Danger
Cleaning agent residues can
result in poisoning.
Always observe the details
provided by the manufacturer
of the cleaning agent.
6. Fully drain any cleaning agent.
7. Flush the DHW cylinder thoroughly
after cleaning.
Check magnesium anode F.
We recommend you replace the magne-
sium anode if the diameter has been
reduced down to 7 10−15 mm.
(cont.)