Eubank SH Series Installation, Operation And Maintenance Manual

Ultra quiet 10+ eer wallmount heat pumps

Advertisement

Quick Links

Installation, Operation and Maintenance
SH SERIES
Ultra Quiet 10+ EER
Wallmount Heat Pumps
REV. 7/7/14
1
3090032.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SH Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Eubank SH Series

  • Page 1 Installation, Operation and Maintenance SH SERIES Ultra Quiet 10+ EER Wallmount Heat Pumps REV. 7/7/14 3090032.
  • Page 2: Inspection And Unpacking

    Your equipment is covered by a LIMITED WARRANTY against In all cases, the equipment MUST be installed in accordance defects in material and workmanship. with the installation instructions described in this manual. This is a vertical, wallmount unit designed for many different WARNING: IMPROPER INSTALLATION MAY applications in both residential and commercial settings.
  • Page 3: Unit Preparation

    TO CLEAN FRESH AIR INTAKE FILTER: C. UNIT PREPARATION A. Follow steps A and B at left “TO CHANGE SYSTEM FILTER”. The S Series model units have a separate top rain B. Gently pull out the filter from the bottom. flashing accompanying the unit.
  • Page 4 STAGING OF ELECTRIC HEAT heat kit is to be installed, follow the instructions included with SH series units with electric heat assemblies are wired for two the heater assembly. stage heat in normal operation. The first stage is refrigerant heat See Figure 1 for reference.
  • Page 5: Cooling Mode

    The outdoor fan is wired through the N/C Eubank wallmount air conditioners and heat pumps have the points of the control’s relay and the N/O points of the ability to equip a variety of options: contactor.
  • Page 6: Defrost Mode

    10 minutes. O. HIGH-PRESSURE LOCK OUT DEFROST TIME SELECTION SH Series units are equipped with a high-pressure switch. The defrost control has three selectable time intervals: 30, This switch is wired through a lockout relay to lock out the 60 and 90 minutes.
  • Page 7 EXPLODED PARTS DRAWING - 36/48/60 REV. 7/7/14 3090032.
  • Page 8 PART NUMBER DESCRIPTION TH36S TH36T TH36D TH48S TH48T TH48D TH60S TH60T TH60D 3020017 COMP ZPS30K5EPFV130 3020018 COMP ZPS30K5ETF5130 3020019 COMP ZPS30K5ETFD130 3020020 COMP ZPS40K5EPFV130 3020021 COMP ZPS40K5ETF5130 3020022 COMP ZPS40K5ETFD130 3020023 COMP ZPS51K5EPFV130 3020024 COMP ZPS51K5ETF5130 3020025 COMP ZPS51K5ETFD130 COND-H436 OUTDOOR COIL 3070001 OUTDOOR COIL...
  • Page 9 PART NUMBER DESCRIPTION TH36S TH36T TH36D TH48S TH48T TH48D TH60S TH60T TH60D T60-0017B COMPRESSOR ACCESS DOOR HV48-60 2022-5015 LOWER CONDENSER GRILL HV36 2023-5015 LOWER CONDENSER GRILL HV48-60 659930 AIR FILTER DISPOSABLE 16x30x1 HV36 3090005 AIR FILTER PLEATED 16x30x2 HV36 659926 AIR FILTER DISPOSABLE 20x30x1 HV48-60 659924 AIR FILTER PLEATED 20x30x2 HV48-60...
  • Page 10 SH SERIES HEAT PUMP ELECTRICAL DATA SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT No. of Model No. & MINIMUM MAX OVER FIELD POWER MAX OVER FIELD POWER Volt / GROUND MIM WIRE GROUND Field Electric CIRCUIT CURRENT WIRE SIZE CURRENT WIRE SIZE...
  • Page 11 REV. 7/7/14 3090032.
  • Page 12 REV. 7/7/14 3090032.
  • Page 13 REV. 7/7/14 3090032.
  • Page 14 UNIT NOMENCLATURE TV 36 S 10 - F B 00 MODEL SERIES OPTION CODE TV = AIR CONDITIONER 10 EER SERIES (UP TO 5 CHARACTERS) TH = HEAT PUMP 10 EER SERIES TR = REFRIGERATION SERIES CABINET COLOR SV = AIR CONDITIONER LOW SOUND SERIES B = MESA TAN (Std) SH = HEAT PUMP LOW SOUND SERIES W = WHITE...