Refrigerant Piping; Tuyaux De Refrigerant; Tubazione Del Refrigerante; Tubo De Refrigerante - Toshiba RAS-M10GDCV-E Installation Manual

Toshiba air conditioner (multi-split type)
Hide thumbs Also See for RAS-M10GDCV-E:
Table of Contents

Advertisement

7 REFRIGERANT PIPING

Refrigerant Piping
1.
If the outdoor units are to be mounted on a wall, make sure that the platform supporting is sufficiently strong. The platform should
be designed and manufactured to maintain its strength over a long period of time, and sufficient consideration should be given to
ensuring that the outdoor unit will not fall.
2.
Use copper pipe with 0.8 mm or more thickness.
3.
Flare nut and flare works are also different from those of the conventional refrigerant.
Take out the flare nut attached to the main unit of the air conditioner, and use it.
CAUTION
IMPORTANT 4 POINTS FOR PIPING WORK
1.
Take away dust and moisture from the inside of the connecting pipes.
2.
Tight connection (between pipes and unit)
3.
Evacuate the air in the connecting pipes using VACUUM PUMP.
4.
Check the gas leakage (connected points).
Flaring
Insert a flare nut into the pipe, and flare the pipe. As the flaring sizes of R410A differ from those of refrigerant R22, the flare tools
newly manufactured for R410A are recommended.
However, the conventional tools can be used by adjusting projection margin of the copper pipe.
• Projection margin in flaring: B (Unit: mm)
• Flaring size: A (Unit: mm)
* In the case of flaring for R410A with the conventional flare tool, pull out it approx. 0.5 mm more than that for R22 to adjust to the
specified flare size. The copper pipe gauge is useful for adjusting projection margin size.
Rigid (Clutch type)
Outer diameter of copper pipe
6.35
9.52
12.7
Imperial (Wing nut type)
Outer diameter of copper pipe
6.35
9.52
12.7
Outer diameter of copper pipe
6.35
9.52
12.7
R410A tool used
R410A
R22
0 to 0.5
(Same as left)
0 to 0.5
(Same as left)
0 to 0.5
(Same as left)
R410A
1.5 to 2.0
1.5 to 2.0
2.0 to 2.5
R410A
9.1
13.2
16.6
13
Conventional tool used
R410A
R22
1.0 to 1.5
0.5 to 1.0
1.0 to 1.5
0.5 to 1.0
1.0 to 1.5
0.5 to 1.0
R22
1.0 to 1.5
1.0 to 1.5
1.5 to 2.0
+0
A
–0.4
R22
9.0
13.0
16.2