Lighting Instructions - Heat & Glo ATS-AU-D Installation And Operation Instructions Manual

Heat & glo ats-au-d gas fireplace installation and operation instructions
Table of Contents

Advertisement

2.3 LIGHTING INSTRUCTIONS

1. "STOP!"
Read the safety information on
previous page.
2. To access controls, open the bottom grille.
3. Turn the valve control knob to the "OFF"
position. To do this, you must turn the knob
clockwise
then press in and continue turning clockwise
to the "OFF" position.
GAS CONTROL VALVE
NOTE: Knob cannot be turned from "PILOT"
to "OFF" unless knob is pushed in slightly. Do
not force.
4. WAIT FIVE (5) MINUTES TO CLEAR OUT
ANY GAS. Then smell for gas, including near
the fl oor. If you then smell gas, STOP! Follow
"B" in the safety information above. If you
don't smell gas, go to the next step.
5. The pilot should not require accessing for
lighting purposes. The pilot is located inside
the combustion chamber. If it is necessary
to access the pilot, follow the instructions in
Section 3.1 and 3.3 for glass door removal
and replacement.
1. Turn ON/OFF switch to "OFF".
2. Open the bottom grille.
LIGHTING INSTRUCTIONS
to the "Pilot" position, and
TO TURN OFF GAS APPLIANCE
Heat & Glo • ATS-AU-D • 327-900 Rev. F • 6/09
PILOT BURNER
THERMOCOUPLE
6. To put the control in the pilot position, turn the
control knob counter-clockwise
"Pilot" position.
7. To light the pilot depress the control knob and
then depress the red piezo button until it makes a
clicking sound. It may be necessary to repeat this
step. If the pilot does not light after 10 seconds,
go back to step 3. The control knob should be
held down for a MINUTE after pilot ignition.
• If the control knob does not pop out when
released, STOP-shut off the gas supply to the
heater control valve, and IMMEDIATELY call
your service technician or gas supplier.
• If the pilot will not stay lit after two tries, turn
the control knob to the "OFF" position and call
your service technician or gas supplier.
8. After the pilot has been lit, the burner can be
turned on by turning the knob counter-clockwise
to the "ON" position. Flip the ON/OFF
switch to the "ON" position.
9. Close the bottom grille.
3. Turn the valve control knob clockwise
to the "Pilot" position, then depress knob and continue
turning to "OFF" position.
4. Close the bottom grille.
THERMOPILE
to the
17