• The REPEATER port boosts the data signal
for longer chains. Use the REPEATER port
instead of LOOP OUT on every 32nd
iMOPS unit in a chain, or when the cable
run between two power supplies is more
than 400 feet. Make sure a terminator is
installed in the LOOP OUT port if the
REPEATER port is used. (See Fig. 7.)
Fig. 7
Auxiliary
OUT 1
OUT
IN
Data In
Loop Out
Repeater Out
F1
Data In Loop Out
Repeater
To sending iMOPS
To receiving iMOPs
or controller
Terminator
Connecting Power to the
Power Supply
NOTE: It is the end user's responsibility to
use the proper conductors to permanently
mount the incoming facility power, and to
provide means for disconnecting the system.
• Set the voltage switch to 115 or 230V AC,
depending on your source voltage.
(See Fig. 8.) The unit is set to 230V AC as
a factory default.
Fig. 8
Voltage switch
• Pass the power supply line through one of
the 3/4" holes in the metal housing. Attach
the appropriate conduit connector. Connect
power lines to the wires labeled N (neu-
tral), L (line), and
(ground). (See Fig. 9.)
1
Fig. 9
Power supply line
Housing ground wire
OUT 2
F2
• Connect the housing ground wire to the
threaded post in the housing. (See Fig. 9.)
• Ensure that the unit is mounted inside the
housing by lining up the two tabs on the
power supply backplate with the two slits
on the inside of the housing. The unit may
need to be inserted at a slight angle as
shown in Fig.10 to slide the tabs in easily.
Fig. 10
Once the tabs are in place, attach the back-
plate to the housing using three of the #6-32
screws. (See Fig.11). A power screwdriver is
recommended for this step.
Fig. 11
Backplate screws
• Place the cover on the housing, making
sure that the vent holes are located above
the power supply for proper ventilation,
and secure the cover using the remaining
four #6-32 screws. A power screwdriver is
recommended for this step.

Replacing Fuses

WARNING: Make sure the power supply is
off before connecting or disconnecting fuses.
Each of the main output terminals is
L (Line)
N (Neutral)
equipped with a fuse. (See Fig. 12.) If an
1
(Ground)
output terminal is not functioning, replace the
fuse as follows:
• Remove the fuse from the malfunctioning
terminal. (The fuse terminals are marked F1
for Output 1, and F2 for Output 2.)
• Insert the replacement fuse in the fuse
terminal. (See Fig. 12.) Use only fuses with
the same type and rating as the original.
Additional replacement fuses are available
from Color Kinetics.
Fig. 12
Auxiliary
OUT
IN
Data In
Loop Out
iMOPS-150 Specifications
Power Output 6 A @ 24 V DC (150 W)
Power Input
Packaging
Dimensions
Connectors
Listings
Data Interface DMX512 (RS485)
ONE YEAR LIMITED HARDWARE WARRANTY
Color Kinetics Incorporated warrants its products, if
properly used and installed, will be free from defects
in materials and workmanship and will substantially
conform to Color Kinetics' publicly available specifica-
tions for a period of one (1) year after the date the
product was purchased by the end user.
If the product fails during the warranty period, pur-
chaser's remedy under this limited warranty shall be at
Color Kinetics sole election:
• Repair the product by means of hardware and/or
software or
• Replace the product with another product or
• If Color Kinetics is unable to repair or replace the
particular product, refund the then current value of
the product.
This limited warranty does not cover damages due to
external causes, including, but not limited to, accident,
problems with electrical power, usage not in accor-
dance with product instructions, misuse, neglect, modi-
fication, repair, improper installation, or improper test-
ing. Color Kinetics is not responsible for indirect, inci-
dental, or consequential damages resulting from any
breach of warranty or under any other legal theory
including, but not limited to, lost profits, downtime,
goodwill, damage to or replacement of equipment
and property.
To obtain warranty service, you may contact your dis-
tributor in accordance with its instructions, or you may
OUT 1
OUT 2
contact Color Kinetics. To request warranty service
you should call Color Kinetics during the warranty
period. Proof of purchase or registration is required.
Repeater Out
When calling within warranty, please provide:
F1
F2
1) Your name, shipping address, and telephone num-
ber
Fuse terminal
2) A description of the model and serial number
Fuse
3) An explanation of the problem
A Return Authorization (RA) number & ship-to address
will be provided to send the product back.
The warranty and remedies set forth above are exclu-
sive and in lieu of all others, whether oral or written,
115/230 V AC
express or implied. Color Kinetics specifically dis-
(user-selectable)
claims any and all implied warranties, including, with-
Includes (2) 50' master
out limitation, warranties of merchantability and fitness
for a particular purpose. No Color Kinetics distributor,
cables and NEMA-style
dealer, agent or employee is authorized to make any
enclosure for installation
modification, extension, or addition to this warranty.
with power supply
This warranty gives you specific legal rights, and you
may also have other rights that vary from jurisdiction
10.5" X 7.5" X 2.7"
to jurisdiction.
Screw terminal or RJ45
MANUFACTURING STANDARDS
data input and output con-
Color Kinetics products are manufactured in the USA,
Ireland, and China.
nectors; screw terminal
U.S. AND FOREIGN PATENTS AND PATENTS
power output connectors
PENDING
UL listed, CE certified
Color Kinetics Incorporated grants the purchaser of its
lighting products and controllers a personal and non-
transferable license to use Chromacore™, its patented
compatible
technology for networkable control of LED-based color-
changing lighting fixtures for illumination, display and
design. This license is granted only by Color Kinetics
Incorporated, and may not be transferred except by
the grantor. The design, duplication, manufacture, or
sale of other products using networkable control of
LED-based color-changing lighting may be prohibited
and is not licensed hereunder. Other patents pending.

Advertisement

loading
Need help?

Need help?

Do you have a question about the i mops- 150 and is the answer not in the manual?

Subscribe to Our Youtube Channel