4-4.Jig Connections

Note1: Connect all jigs and start PC.
Note2: Do not connect the video cable with "VIDEO OUT" Jack of the camera, except when you adjust the video.
Note3: Input voltage is a thing measured in a part near "DC_IN" Jack.
Note4: Limit the current value to 2.5A or less.

4-5.Environmental Setup

(1) Environmental Setup for Camera Adjustments (Fig. A)
<<All White Pattern>>
Set the pattern box within 50 mm of the camera's refer-
ence surface (*1).
Set the filter (LB140) against the pattern box.
1. Color temperature: 6100
Measurement point : Center of pattern box
Measuring decvice
: Camera Meter III (Minolta)
or similar product
* How to Measure Color Temperature
Set the filter (LB140) against the pattern box. With the filter
(LB140) contacting the pattern box, adjust color tempera-
ture of the pattern box to 6100
2. Brightness: 160
+
5 cd/m2 (With LB140 filter)
Measurement point : Center of pattern box
Measuring device
: Brightness meter LS-110
(Minolta) or similar product
* How to Measure Brightness
Set the filter (LB140) against the pattern box. With the filter
(LB140) contacting the pattern box, adjust brightness of the
+
pattern box to 160
5 cd/m2.
+
50K (With LB140 filter)
+
50K.
4.Adjustments
<Fig. A> Adjustment environment
*1. The camera's reference surface is the front face of the lens
assembly when the lens is to the wide end.