Qmark CWH 3000 Installation & Maintenance Instructions Manual

Series b fan forced wall heaters
Table of Contents

Advertisement

Available languages

Available languages

CWH 3000
(Series B)
Fan Forced
Wall Heaters
Installation & Maintenance Instructions
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered
Products. You have made a wise investment selecting the highest quality product in the heating indus-
try. Please carefully read the installation and maintenance instructions shown in this manual. You
should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the
industry's leader in design, manufacturing, quality and service.
Read Carefully - These instructions are written to help you prevent
difficulties that might arise during installation of heaters. Studying
the instructions first may save you considerable time and money
later. Observe the following procedures and cut your installation
time to a minimum. TO REDUCE RISK OF FIRE OR ELECTRIC
SHOCK:
1. Disconnect all power coming to heater at main service panel
before wiring or servicing.
2. All wiring must be in accordance with the National and Local
Electrical Codes and the heater must be grounded.
3. Verify the power supply voltage coming to heater matches the rat-
ings printed on the heater nameplate before energizing.
4. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces.
5. Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock, fire, or
WARNING
!
SAVE THESE INSTRUCTIONS
1
15-25/32"
(400mm)
FILE #E21609
... The Employees of
Marley Engineered Products
damage to the heater.
6. Do not block air intakes or exhaust in any manner. Keep com-
bustible materials, such as crates, drapes, etc., away from
heater. Do not install behind doors, furniture, towels, or boxes.
7. A heater has hot and arcing (sparking) parts inside. Do not use
it in areas where gasoline, paint, or flammable liquids are used
or stored.
8. Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock, or injury to persons.
9. This heater is not approved for use in corrosive atmospheres,
such as marine, green house, or chemical storage areas.
10. Do not install heater upside down or sideways. Do not use
heater without grille.
11. For wall mounting only. Do not install heater closer than
8" (203 mm) to the floor or any adjacent wall surface. Do not
install closer than 36" (915 mm) to the ceiling.
1-1/2"
(38mm)
3-3/4"
(95mm)
19-3/16"
(487mm)
18-1/4"
(464mm)

Advertisement

Table of Contents
loading

Summary of Contents for Qmark CWH 3000

  • Page 1 1-1/2" 15-25/32" (38mm) (400mm) 3-3/4" (95mm) CWH 3000 19-3/16" (487mm) 18-1/4" (464mm) (Series B) Fan Forced Wall Heaters FILE #E21609 Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating indus- try.
  • Page 2 NOTE: This heater has a continuous fan-only feature. See page 3 for details. Installation of Recessed Back Box in New Construction 1. Mounting Back Box (See Figure 1). a. Place the back box between two 16" (406 mm) center-to- center wall studs at the desired mounting height but no closer than 8"...
  • Page 3: Wiring Diagrams

    5. Push disconnect switch into ON position. MOUNT BACK 6. Mount the grille using the four (4) long screws provided. BOX TO WALL The screws thread into holes located in the side flanges USING REAR 3-13/16" (97mm) MOUNTING of the back box. BRACKETS 7.
  • Page 4: Maintenance

    NOTE: For best results, the heater should be left “ON” constant- WIRING DIAGRAMS (Conʼt) ly during the heating season because the thermostat, when prop- erly set, will maintain the desired temperature. L2/N Maintenance Disconnect TO RESET MANUAL RESET LIMIT Switch Your heater is equipped with a manual reset safety thermal limit Heat Fan Only...
  • Page 5: Replacement Parts

    Replacement Parts Description Part Number Knob 3301-2016-000 Grille 2501-2019-001 Element: CWH1512 120V/1500W 302012827 CWH1812 120V/1800W 302012828 CWH3208B 208V/2000W 302015801 CWH3408B 208V/4000W 302012807 CWH34083B 208V/4000W/ 3Ph. 1802-2075-800 CWH3508B 208V/4800W 1802-2075-801 CWH35083B 208V/4800W/3Ph. 1802-2075-801 CWH3204B 240V/2000W 302015802 CWH3404B 240V/4000W 302012808 CWH34043B 240V/4000W/3Ph. 1802-2075-802 CWH3504B 240V/4800W...
  • Page 6 Notes:...
  • Page 7 19-3/16" (487mm) 18-1/4" Calentadores de Pared (464mm) de Tiro Forzado CWH 3000 (Serie B) EXPEDIENTE NO. E21609 Instrucciones de Instalación y Mantenimiento Estimado propietario: ¡Felicitaciones! Gracias por comprar este nuevo calentador fabricado por Marley Engineered Products. Usted ha efectuado una sabia inversión al seleccionar el producto de la más alta calidad en la industria de calefacción. Por favor lea cuidadosamente las instrucciones de instalación y mantenimiento indicadas en este manual.
  • Page 8 NOTA: Este calentador tiene una característica continua de ventilador sola- mente. Vea la página 4 por los detalles. Instalación de la Caja Posterior Empotrada en Nueva Construcción 1. Montaje de la Caja Posterior (Vea la Figura 1) a. Coloque la caja posterior entre dos montantes de pared de 16" (406mm) de centro a centro a la altura deseada de montaje pero no más cercano que 8"...
  • Page 9 5. Mueva el conmutador desconectador a la posición ON. MONTE LA CAJA 6. Monte la rejilla usando los cuatro (4) tornillos largos provistos. Los POSTERIOR A LA PARED USANDO torni-llos se enroscan dentro de los orificios ubicados en las bridas 3-13/16"...
  • Page 10 4. Habrá una breve demora desde el momento en que se enciende DIAGRAMAS DE CABLEADO (Cont.)(TODOS 1 FASE) la unidad hasta que se engancha el ventilador. Esto es para per- mitir tiempo a los elementos para que se calienten. También, el Diagrama 4 ventilador continuará...
  • Page 11: Piezas De Repuesto

    Piezas de repuesto Nº clave Descripción Número de parte Perilla 3301-2016-000 Rejilla 2501-2019-001 Elemento: CWH1512 120V/1500W 302012827 CWH1812 120V/1800W 302012828 CWH3208B 208V/2000W 302015801 CWH3408B 208V/4000W 302012807 CWH34083B 208V/4000W/trifásico 1802-2075-800 CWH3508B 208V/4800W 1802-2075-801 CWH35083B 208V/4800W/trifásico 1802-2075-801 CWH3204B 240V/2000W 302015802 CWH3404B 240V/4000W 302012808 CWH34043B 240V/4000W/trifásico...
  • Page 12 19-3/16" Radiateurs muraux (487mm) 18-1/4" (464mm) à air pulsé CWH 3000 (Série B) DOSSIER Nº E21609 Instructions d'installation et d'entretien Cher propriétaire, Félicitations! Nous vous remercions d'avoir acheté ce nouveau radiateur fabriqué par Marley Engineered Products. Vous avez fait un bon investissement en choisissant le produit de la meilleure qualité de l'industrie du chauffage.
  • Page 13 REMARQUE: Ce radiateur comporte un dispositif de ventilateur unique- ment en continu. Voir page 4 pour des détails. Installation de boîtier arrière encastré dans une construction neuve 1. Fixation du boîtier arrière (voir figure 1). a. Placer le boîtier arrière entre deux poutres murales espacées de 406 mm centre à...
  • Page 14: Schémas De Câblage

    6. Fixer la grille avec les quatre (4) longues vis fournies. Les vis se vissent dans les trous sur les parois latérales du boîtier arrière. FIXER LE BOÎTIER 7. Pousser le bouton de thermostat sur l'arbre de thermostat. ARRIÈRE AU MUR AVEC LES SUPPORTS DE FIXATION ARRIÈRE...
  • Page 15: Entretien

    4. Il y a un bref délai entre le moment où l'appareil est mis sous ten- SCHÉMAS DE CÂBLAGE (suite) (TOUS Nº 10) sion et le moment où le ventilateur démarre. Ceci permet aux élé- ments de chauffer. Le ventilateur continue également de fonc- Schema 4 tionner après arrêt de l'appareil pour permettre aux éléments de Vers le commutateur de...
  • Page 16: Garantie Limitée

    Identification des pièces de remplacement réf Description Numéro de pièce Bouton 3301-2016-000 Grille 2501-2019-001 Élément: CWH1512 120V/1500W 302012827 CWH1812 120V/1800W 302012828 CWH3208B 208V/2000W 302015801 CWH3408B 208V/4000W 302012807 CWH34083B 208V/4000W/ 3Ph. 1802-2075-800 CWH3508B 208V/4800W 1802-2075-801 CWH35083B 208V/4800W/3Ph. 1802-2075-801 CWH3204B 240V/2000W 302015802 CWH3404B 240V/4000W 302012808...

Table of Contents