Qmark DBA Installation, Operation & Maintenance Instructions Manual

Qmark DBA Installation, Operation & Maintenance Instructions Manual

Architectural sill-height convection heaters
Table of Contents

Advertisement

Available languages

Available languages

DBA and SHA
Architectural Sill-Height
Convection Heaters
Installation, Operation & Maintenance Instructions
GENERAL
This heater is designed to provide years of efficient, trouble free operation as a primary or supplemental heat source for comfort
heating in residential (Model DBA only at 250 watts per linear foot) and commercial applications. Installation or use of this product
in any manner not described within this manual will void the warranty and could result in injury, damage to property, or permanent
damage to heater.
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO
PERSONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using the heater.
2. A heater has hot and arcing or sparking parts inside. Do not
use in areas where gasoline or flammable liquids are used
or stored.
3. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and cur-
tains away from heater.

IMPORTANT INSTRUCTIONS

WARNING
SAVE THESE INSTRUCTIONS
H
W
!
4. To prevent a possible fire, do not block air intakes or
exhaust in any manner.
5. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock or
fire, or damage the heater.
6. Serious injury or death could result from electric shock.
Make sure electrical power supply circuit coming to heater
is disconnected at main disconnect or service panel before
installing or servicing this heater.
7. DBA model with 250 watt a linear foot or less, without wire
mesh, are UL approved for residential use. Model SHA is
not for residential or household use.
L
Dimensions
Type Height Width
Length
6"
3-5/8"
28" to 15'
DBA
152mm
92mm
711mm to 4572mm
7"
5-3/8"
28" to 12'
SHA
178mm
136mm 711mm to 3658mm

Advertisement

Table of Contents
loading

Summary of Contents for Qmark DBA

  • Page 1: Important Instructions

    This heater is designed to provide years of efficient, trouble free operation as a primary or supplemental heat source for comfort heating in residential (Model DBA only at 250 watts per linear foot) and commercial applications. Installation or use of this product in any manner not described within this manual will void the warranty and could result in injury, damage to property, or permanent damage to heater.
  • Page 2 Table A - DBA & SHA (one element) (two and three element) Amperage Amperage Catalog Length Watts Total Catalog Length Watts Total 208V 240V 277V 347V 600V Number "L" per ft. Watts 120V 208V 240V 277V 347V 600V Number "L"...
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS Rough in Wire 1. Run branch circuit of proper voltage and wire size to location of left or right junction box as indicated on heater wiring dia- gram. Basic heaters are prewired and can be connected to TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK branch circuit at either end.
  • Page 4 Putty knife or Cabinet front other wide blade cover Junction tool Ground Cabinet Screw Recommended Back Run ground mounting holes Housing wire thru top drill area or bottom hole. Wrap around ground screw and tighten screw. Fig. 1 Fig. 4 Floor pedestal mounted, consult pedestal kit installation instruc- 10.Replace front cover by latching the bottom front edge of the...
  • Page 5: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS Your heater will give your years of service and comfort with only minimal care. The user can perform periodic cleaning of the exterior cabinet, but all other interior cleaning and servicing should be done by a qualified service person. Back lignment Housing...
  • Page 6: Limited Warranty

    Typical Wiring of Multiple Heaters (without controls) Thermal Protector Thermal Protector Element Element Ground Screw To other Ground Screws To other heater heater No. 10 Wires No. 10 Wires Factory Wiring Field Wiring Power Supply to Circuit Breaker Fig. 7 LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation.
  • Page 7: Instrucciones Importantes

    Este calefactor está diseñado para proporcionar muchos años de funcionamiento eficiente y sin problemas como fuente de calor principal o complementaria para calefacción ambiental, en aplicaciones residenciales (modelo DBA únicamente a 820 watts por metro lineal / 250 watts por pie lineal) y comerciales. La instalación o uso de este producto de cualquier manera no descrita en este manual anulará...
  • Page 8 Tabla A: DBA y SHA ( un elemento) SHA (dos y tres elementos) Corriente, A Corriente, A Número Longitud Watts Watts de catálogo ‘L’ por pie. totales 120 V 208 V 240 V 277 V 347 V 600 V Número...
  • Page 9: Instrucciones De Instalación

    INSTRUCCIONES DE INSTALACIÓN Cables de instalación 1. Realice el tendido de un circuito de derivación, de la tensión y cali- bre de cables adecuado, hasta la ubicación de la caja de conex- iones izquierda o derecha, como se indica en el diagrama de conex- ionado del calefactor.
  • Page 10 Espátula u otra Putty knife or Cubierta frontal Cabinet front herramienta de hoja other wide blade del gabinete Junction cover ancha tool Ground Screw Área recomendada Cabinet Caja trasera Recommended para la perforacion Back Run ground del gabinete mounting holes wire thru top Housing de los agujeros de...
  • Page 11: Instrucciones De Operación

    INSTRUCCIONES DE MANTENIMIENTO Su calefactor le brindará muchos años de servicio y confort con sólo un mínimo de cuidado. El usuario puede realizar una limpieza periódica del gabinete exterior, pero todo el resto de la limpieza interior y servicio debe estar a cargo de personal de servicio calificado. Caja Aleta de Nota: para garantizar una operación eficiente y segura, la circulación de...
  • Page 12: Garantía Limitada

    Conexionado típico de calefactores múltiples (sin controles) Protector térmico Thermal Protector Protector térmico Thermal Protector Element Elemento calefactor Elemento calefactor Element Tornillo de pues- Ground Screw ta a tierra Al otro To other Tornillo de Ground Screws To other Al otro calefactor heater puesta a tierra...
  • Page 13: Instructions Importantes

    Ce radiateur est conçu pour fournir des années de fonctionnement sans soucis comme source de chaleur principale ou auxiliaire, pour du chauffage de confort dans des applications résidentielles (Modèle DBA à 250 W par pied de longueur) et commerciales. L’installation ou l’utilisation de ce produit d’une quelconque manière non décrite ici annulera la garantie et pourrait entraîner des blessures, des dégâts matériels ou des dommages permanents sur le radiateur.
  • Page 14 Tableau A - DBA et SHA (un élément) SHA (deux ou trois éléments) Ampérage Ampérage N° au longueur Watts Total en 208 V 240 V 277 V 347 V 600 V N° au longueur Watts Total en catalogue "L" par pied...
  • Page 15: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Câblage de préparation 1. Tirez une branche de circuit secteur, avec la bonne tension et une taille de fils correcte, jusqu’à l’emplacement du boîtier de raccorde- ment de gauche ou de droite, comme indiqué sur le schéma de POUR RÉDUIRE LE RISQUE DE DÉPART D’INCENDIE, DE COM- câblage du radiateur.
  • Page 16 Couteau à mastiquer Putty knife or Couvercle avant Cabinet front ou autre outil à lame other wide blade du coffret Junction cover large tool Ground Screw Zone de perçage Cabinet Carter arrière Recommended recommandée Back Run ground du coffret mounting holes wire thru top Housing pour les trous de...
  • Page 17: Instructions D'utilisation

    INSTRUCTIONS D’ENTRETIEN Votre radiateur vous fournira des années de bon service et de confort avec juste un minimum de soins. L’utilisateur peut effectuer lui-même un nettoyage périodique de l’extérieur du coffret, mais toutes les autres interventions de nettoyage de l’intérieur et de service doivent être faites Carter par une personne de service qualifiée.
  • Page 18: Garantie Limitée

    Câblage type pour plusieurs radiateurs (sans commandes) Protecteur thermique Thermal Protector Protecteur thermique Thermal Protector Element Élément Element Élément Vis de terre Ground Screw Vers un autre To other Vis de terre Ground Screws To other Vers un autre radiateur heater heater radiateur...