3.3.1 Default Threshold Values

Table 3-7 shows the default threshold values for the Galaxy GHDX2-2130-
16iSCSI subsystem. If any of these values are surpassed, the alarm will
sound:
+3.3V
+5V
+12V
CPU Temperature
Controller Board
Temperature
Enclosure Ambient
Temperature
The thresholds in Table 3-7 are default threshold values and may be
changed. To see how to change these values, please refer to the Generic
Operation Manual on the CD that came with your system.

3.3.2 Failed Devices

If any of the following components fails, the audible alarm will be triggered:
When temperature exceeds a preset threshold, the controller's charger
circuits will stop charging. You will then receive a message that says
"Thermal Shutdown/Enter Sleep Mode." When the temperature falls
back within normal range, the battery will resume charging.
Audible Alarm
Upper Threshold
Table 3-7: Default Threshold Values
RAID controller module
Cooling fan modules
PSU modules
BBU module
Hard disk drives
NOTE:
Chapter 3: Subsystem Monitoring
Lower Threshold
+3.6V
+5.5V
+13.2V
90ºC
80ºC
40ºC
+2.9V
+4.5V
+10.8V
5ºC
5ºC
0ºC