management. Two (2) power cords are provided for the power
connections to the power sources. For the compliance with listed
emission standard, RJ-45 STP cables should be applied. Rorke provides
certified cables as an optional accessory. One 3-meter STP Ethernet
cable is available as an accessory option. Please see Chapter 4 for
sample topologies and configuration options.
5. Memory module: If you wish to change the pre-installed memory
module, a separately purchased module can be installed. (See Section
5.3)
6. BBU module: If you wish to use a BBU module, the module can be
purchased separately. For installation instructions, please see Section
2.7.
7. Rack installation: The enclosure chassis can be installed into a rack
cabinet using separately purchased mounting rails, or Rorke's GAL-
DX-RACK-KIT slide rails. (See Section 2.10)

2.3 Safety Precautions

2.3.1 Precautions and Instructions

1. Disconnect the power cords if the need should arise for cleaning the
chassis. Do not use liquid or sprayed detergent for cleaning. Use a
lightly moistened clothe for cleaning.
2. Be sure the correct power range (100-120 or 220-240VAC) is supplied
by your rack cabinet or power outlet. It is highly recommended to
connect two different power supplies to separate power sources; e.g.,
one to a power outlet, and the other to a UPS system.
3. Thermal notice: All drive trays (even if they do not contain a hard
drive) must be installed into the enclosure. Leaving a drive bay or
module slot open will severely affect the airflow efficiency within the
enclosure, and will consequently lead to system overheating. Keep a
faulty module in place until you have a replacement unit and you are
ready to replace it.
4. Rack-mounting: The subsystem is intended to be rack-mounted.
Following concerns should be heeded when mounting the enclosure
into a rack cabinet:
2-2
a.
An enclosure without disk drives can weigh over 30 kilograms.
Two (2) people are required to install or relocate the
subsystem. Drives should be removed from the enclosure
before moving the subsystem.
Safety Precautions