10. Installation

10.2 Selection of the best location

① There should not be any heat or steam near the unit.
② Select a place where there are no obstacles around of
the unit.
③ Make sure that condensation drainage can be conve-
niently routed away.
④ Do not install near a doorway.
⑤ Use a metal detector to locate studs to prevent unneces-
sary damage to the wall.
More than
100(3-15/16)
Recommended height
2000(78-3/4)
Note : Remove obstructions to prevent blockage of air-
flow path

10.3 Fixing installation plate

The wall you select should be strong and solid enough to
prevent vibration
① Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete wall,
use anchor bolts.
• Mount the installation plate horizontally by aligning the
centerline using Horizontal meter .
Installation Plate
Chassis
Hook
16 _
Wall mounted
Indoor unit
More than
200(7-7/8)
More than
100(3-15/16)
Unit : mm(inch)
Type "A" Screws
② Measure the wall and mark the centerline. It is also
important to use caution concerning the location of the
installation plate. Routing of the wiring to power outlets is
through the walls typically. Drilling the hole through the
wall for piping connections must be done safely.
Place a level on raised tab
Unit Outline
Ø70
(Ø2 3/4)
Installation Plate
133(5 1/4)
175(6 7/8)
10.4 Before piping work
CAUTION
• Installation Information. For right piping. Follow the
instruction given below.
Good case
• Press on the upper side of clamp and unfold the tubing to
downward slowly.
Ø70
(Ø2 3/4)
95(3 3/4)
217(8 17/32)
Unit : mm(inch)