K4C COMPACT-MULTI – INSTALLATION/OPERATION MANUAL
Using too much oil
Oil leak in line or tank
Draft regulator set high
Nozzle too large
Burner reset cuts out
No oil
Frozen oil line
Dirty oil filter
Dirty nozzle, smoky fire
Faulty oil pump
Faulty or dirty electrodes
Warm air register blowing cold air
Basement cooling ducts
Ducts running through
unheated spaces
Low speed switch is on
"FAN OFF" set low
Motor speed set too high
Warm air registers blowing too hot
Blower running slow
Return air restricted
Nozzle too large
All rooms at different temperatures
Supply air not regulated
Return air not regulated
Noisy operation
Loose blower wheel
Blower wheel hitting housing
Damaged motor bearings
Faulty oil pump
Air leak in oil line
Vacuum too high on pump
K4C Compact-multi
Check fittings for tightness. Inspect tank and replace
if necessary.
Adjust regulator for -0.04" wc draft pressure at
breech.
Replace nozzle to lower input.
Call oil supplier.
Call technician or oil supplier.
Replace filter.
Replace nozzle, adjust burner air.
Have pump replaced, adjust burner air.
Have technician clean or replace.
Insulate
and
seal
temperature.
Change or insulate ductwork.
Switch off blower low speed.
Fan control – Set "FAN OFF" higher.
Reset motor speed to slow blower.
Speed blower up.
Open up return air ductwork to ensure adequate air
flow.
Lower nozzle size to suit ductwork.
Adjust warm air regulators to suit each room.
Check for sufficient return air.
Tighten wheel set screw or replace.
Center wheel in housing.
Replace blower motor.
Repair or replace oil pump.
pressure.
Tighten all connections.
Check pump vacuum.
screen.
15
ductwork
to
maintain
Reset to correct
Check filters and pump
duct
Feb
-06