Summary of Contents for Zynex Medical E-wave

  • Page 1 Page 1 Muscle Stimulation...
  • Page 2: Table Of Contents

    Page 2 Table of Contents: Customer Service / Supplies / Support Get Started with the E-Wave Controls and Features Factory Settings Electrodes and Skin Care Batteries Indications Contraindications Safety Warnings Pg 10 Precautions Pg 11 Technical Specifications Caution: Federal Law restricts this device to sale by or on the order of a practitio- ner licensed by the law of the State in which he/she practices to use or order the use of the device.
  • Page 3: Customer Service / Supplies / Support

    Page 3 Zynex Medical Contact Information CUSTOMER SERVICE (866) 940-7030 Supplies: To order more electrodes or other accessories Technical Support: Questions or problems with using your device Device Return: Order a postage paid return envelope to return your device at no charge...
  • Page 4: Get Started With The E-Wave

    OFF to turn the unit off. It takes one additional second after reaching 0 mA to turn it off. If no controls have been touched for 60 seconds with level at 0 mA or 60 seconds after timeout, the E-Wave will automatically turn off.
  • Page 5 Page 5 Setting Stimulation Level: Use the ↑ and ↓ controls to increase or decrease the intensity. Do not use the PRG button. After 20 seconds the stimulation level is electronically locked as a safety feature to prevent the patient from unintentional increase in stimulation.
  • Page 6: Factory Settings Pg

    The Off-time is now disabled and a stimulation cycle will only begin, when the switch is activated. The set parameters for On-time, Ramp Up and Down will be in effect for a stimulation cycle. This functionality is enabled as soon as the connector is inserted into the E-Wave.
  • Page 7: Electrodes And Skin Care

    If necessary, remove excess body hair. The E-Wave is intended to be used with re-usable, self-adhesive electrodes. Extended number of uses can be obtained by adding water to the adhesive surface immediately after each use and placing them on the plastic pad.
  • Page 8: Indications

    Indications, contraindications, precautions, safety and warnings. Safety References Zynex Medical (Zynex) is only responsible for the safety, reliability and function of the device when repairs, adjustments and changes have been carried out by persons authorized by Zynex for such work and the device is used according to the user manual.
  • Page 9: Warnings

    Page 9 Warnings • The long-term effects of chronic electrical stimulation are unknown. • Stimulation should not be applied over the carotid sinus nerves, particularly in patients with known sensitivity to the carotid sinus reflex. • Stimulation should not be applied over the neck or mouth. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing.
  • Page 10: Precautions

    Page 10 Precautions • Safety of powered muscle stimulators for use during pregnancy has not been established. • Caution should be used for patients with suspected or diagnosed heart problems. • Caution should be used for patients with suspected or diagnosed epilepsy.
  • Page 11: Technical Specifications

    Page 11 Technical Specifications Amplitude: 0-100 mA Frequency: 4-100 Hz Factory setting is 30 Hz. Pulse width: 50-300 µsec. Factory setting is 200 µsec. On-Time: 0.5 to 30 seconds Factory setting is 6 seconds. Off-Time: 0.1 to 60 seconds Factory setting is 6 seconds. Ramp Up: 0.1 to 6 seconds Factory setting is 1 second.
  • Page 12 Page 12 9990 Park Meadows Drive, Lone Tree, Colorado 80124 1-800-495-6670 www.zynexmed.com P/N 300240 Rev 02...