INSTALLING CONTEMPORARY MEDIA
NOTE: Turn off all electricity to the appliance
before you install contemporary floor media.
WARNING
• DO NOT attempt to install the
contemporary media until the
appliance installation has been
completed, the gas line con-
nected and tested for leaks and
the initial burner operation has
been checked out.
• The size and position of the
contemporary media was engi-
neered to give the appliance
a safe, reliable and attractive
flame pattern. Any attempt to
use a different media in the
fireplace will void the warranty
and will result in incomplete
combustion, sooting, and poor
flame quality.
• Contemporary media get very
hot and will remain hot up to
one hour after gas supply is
turned off. Handle only when
contemporary media are cool.
• This appliance is not designed
to burn wood. Any attempt to
do so could cause irreparable
damage to the appliance and
prove hazardous to your safety.
• If contemporary media are
not installed according to the
installation instructions, flame
impingement and improper
combustion could occur and
result in soot and/or excessive
production of carbon monoxide
(CO), a colorless, odorless,
toxic gas.
• Only use materials listed here.
Only contemporary media
authorized have been tested
for use within the firebox and
its environment. Do not attempt
to use any different materials
in the fireplace. Doing so may
be dangerous and will void
the warranty and will result in
incomplete combustion, soot-
ing, and poor flame quality.
12
SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
®
Table Of Contemporary Media
Cat.
Model
No.
H7536
MTRS
H7537
MCCG-Ob
H7538
MbSK
H7578
MCCG-DW
H7579
MCCG-Sb
H7581
MbLPK-35ZG
Remove the front glass enclosure panel (see
Removing Glass Enclosure Panels on Page 11).
This fireplace is designed to accept a number
of alternate contemporary media options,
allowing the homeowner to customize this
product to fit any decor.
Install Zen Garden Refractory Panels
(MbLPK-35ZG)
1. Porcelain panels come installed in the ap-
pliance. Remove them by bending the tab,
sliding the left and right side panels out
first, then removing the rear panel.
2. Install Zen Garden panels:
• Remove the lintel by removing two screws.
• Insert the rear panel into firebox and po-
sition against the rear wall of the firebox
(see Figure 6 - Detail A on Page 13).
• Carefully insert the left side panel into
firebox, at a slight angle away from the
sidewall. Position the side panel as far
back along the wall as it will go (until it
is against the rear panel) and lower it into
place, while standing it upright and press-
ing it down over the knife edge at the rear
of the sub-floor. The sub-floor knife edge
will cut into the refractory panel. Repeat
the same procedure for the right side pan-
el (see Figure 6 - Detail B on Page 13).
• Re-install the lintel.
Install Tumbled River Stone (MTRS)
Contemporary Media
IMPORTANT: Refractory panels should be
Name
installed before any of the contemporary
media are installed.
Tumbled River Stone
Contemporary Glass
1. Place stones on the firebox sub-floor, in
Obsidian black
any atheistically pleasing manner to suite
Contemporary beach
individual taste. See Figure 6 - Detail C
Sand
on Page 13 for an example.
Contemporary Glass
Diamond White
IMPORTANT: be sure stones do not im-
Contemporary Glass
pinge on the burner outlet.
Deep Sea blue
Merit Liner Kit, Zen
Garden
Install Crushed Glass And Sand
(MCCG and MbSK)
IMPORTANT: Refractory panels should be
installed before any of the contemporary
media are installed.
1. Pour out glass or sand on firebox sub-
floor, completely covering the sub-floor.
See Figure 6 - Detail D on Page 13 for an
example.
IMPORTANT: Avoid letting glass or sand
fall into the burner outlet. Make sure no
glass or sand falls into the burner ports.
Install Contemporary Facade
1. Refer to the Facade Installation Instruc-
tions (P/N 506019-40) to install the Con-
temporary Facade.