Amana xMVC96 series Installation Instructions Manual page 40

Two-stage gas furnace
Table of Contents

Advertisement

Submenu Item
Heat Airflow Trim (HT TRM)
Heat ON Delay (HT ON
Heat OFF Delay (HT OFF)
Heat Airflow (HT ADJ)
Auxiliary Alarm
Humidity Setting
Humidity Fan Speed
Submenu Item
Mode (MODE)
CFM (CFM)
NON-COMM (APPLIES ONLY TO A COMMUNICATING COMPATIBLE FURNACE MATCHED
WITH A NON-COMMUNICATING COMPATIBLE SINGLE STAGE AIR CONDITIONER)
Submenu Item
Cool Airflow (CL CFM)
Cool Airflow Trim (CL TRM)
Cool Airflow Profile (CL PRFL)
Cool ON Delay (CL ON)
Cool OFF Delay (CL OFF)
SET-UP
User Modifiable Options
-10% to +10% in 2% increments,
default is 0%
5, 10, 15, 20, 25, or 30 seconds,
default is 30 seconds
30, 60, 90, 120, 150, or 180 seconds,
default is 150 seconds
1, 2, 3, or 4
ON / OFF
ON / OFF / IND
1, 2, 3, 4
STATUS
Displays the current furnace operating mode
Displays the airflow for the current operating mode
User Modifiable Options
18, 24, 30, 36, 42, 48, or 60, default
is 18
-10% to +10% in 2% increments,
default is 0%
A, B, C, or D, default is A
5, 10, 20, or 30 seconds, default is
5 seconds
30, 60, 90, or 120 seconds, default
is 30 seconds
Trims the heating airflow by the selected
amount.
Selects the indoor blower heat ON delay
Selects the indoor blower heat OFF delay
Selects the nominal heating airflow (see
Startup Procedure and Adjustment –
Circulator Blower Speeds for addition
information)
Enable or Disable Auxiliary Alarm Input
Select Humidity Relay Functionality. ON -
Humidifier is turned on with heat demand.
OFF - Humidifier remains off. IND - Humidifier
will cycle with humidification demand
(independent of an active heat demand)
Select Humidity Fan Speed (this option is
enabled when Humidity Setting of IND is
selected). 1 - 25%, 2 - 50%, 3 - 75%, 4 -
100% of maximum airflow.
Indication (for Display Only; not User Modifiable)
Selects the airflow for the non-
communicating compatible single stage AC
unit
Selects the airflow trim amount for the non-
communicating compatible single stage AC
unit
Selects the airflow profile for the non-
communicating compatible single stage AC
unit
Selects the indoor blower ON delay for the
non-communicating compatible single
stage AC unit
Selects the indoor blower OFF delay for the
non-communicating compatible single
stage AC unit
40