802SH
Parameter group
Rx Measurement Setup Parameter
Fundamental Measurement
Parameter
Additional information 2: Out-of-range display for W-CDMA
1) VERS command
<Start the test programme.>
VERS = 1
<Check the response.>
2) PUCA command
<Start the test programme.>
MODE=4
WWDL=0
WWDL=1
WWDL=2
WRST=1
PUCA = 1,10837,0,2,5,8,15
(* When MT8820A is used, set up the measurement equipment according to the setting examples for MT8820A.)
<Measurement.>
PUCA = 0 (Measurement is complete.)
WRST = 0
POFF
<Turn off the power.>
3) Mandatory reception mode
<Send CW, 2167.4 MHz from SG.>
<Start the test programme.>
MODE=4
WWDL=0
WWDL=1
WWDL=2
WRXC=10832
TCMP=2,0
RXPW=0
<Check RSSI.>
WRST = 0 (Measurement is complete.)
POFF
<Turn off the power.>
CONFIDENTIAL
Parameter
Bit Error Rate
Number of Sample
BER Upper Limit
Measurement Input
Ext.BER.Input Polarity
Ext.BER.Input Clock
Voice Channel
Block Error Rate
BER/BLER Timeout Length
Power measurement
Frequency Error
Occuupied Bandwidth
Specturm Emission Mask
Adjacent Channel Power
Modulation Analysis
Peak Code Domain Error
BER
BLER
Setting
10000 bit
10%
RF Loopback
10sec
On Average count 1
On Average count 1
On Average count 1
On Average count 1
On Average count 1
On Average count 1
On Average count 1
On
Off
2 – 36
Remarks
Not used
Not used
Not used
Not used