External Reference Clock: 1 x 10M Atomic Clock Input @ 75 Ohms 1Vpp on BNC
A/D Converter:
D/A Converters
Clock Specifications
Clock Aging:
Clock Calibration:
Atomic Clock Input:
Sample Rates (kHz):
Operating Temperature:
Weight:
Dimensions (Approx):
Power Supply:
Fuses:
1 x Word Clock Input @ 75 Ohms 3Vpp on BNC 32 - 192kHz
Dynamic Range 122dB
THD+N -105dB
Main DAC Dynamic Range 127dB
THD+N -107dB
Monitor DAC Dynamic Range 120dB
THD+N -103dB
Headphones DAC Dynamic Range 120dB
THD+N -100dB
<+/-0.02 PPM, oven controlled at 64.5°C/ 148.1°F
< 1 ppm per year
< +/-0.001 ppm
10MHz @ 1Vpp, BNC
32, 44.1, 48, 88.2, 96, 176.4, 192
0-50°C, 32-122°F
3 kg, 6.6 lb approx.
483mm(W) x 44mm(H) x 220mm (D)
19"(W) x 1.75"(H) x 8.66"(D)
~110VAC 60Hz/ ~220VAC 50Hz selectable
2 x 0.8A 250VAC 5mm x 20mm Type T (or Time delay)
Pin layout:
● Pin 1 – Ground
● Pin 2 – Hot
● Pin 3 - Cold