6. Note the orientation of all grease fittings before
removing any yokes or crosses. Remove the
end yoke from the center housing.
7. Repeat steps 2-6 to remove the shaft yoke and
cross from the center housing.
8. Use the hammer and the driver to remove the
two bearing cups from the center housing.
(MntP-R-0162).
9. Remove the snap rings from the end yoke and
the shaft yoke (Refer to Step 2)
10.Set the end yoke on the vise so the trunnions of
the cross are supported by the jaws of the vise.
Hit the end yoke to force the bearing cup out of
the end yoke. The bearing cup will only be
forced part way out of the end yoke. Note: When
hitting the end yoke NEVER hit the area around
the hole in ear. Distortion of the hole will make
removal of the bearing cup difficult. (MntP-R-
0163)
11. Repeat Step 10 to push the other bearing cup
part way out of the end yoke.
12.Fasten one of the bearing cups in the vise. Make
sure the jaws of the vise are as close to the end
yoke as possible. Hit the end yoke to drive the
yoke up off the bearing cup, similar to Step 5.
13.Repeat Step 12 to remove the other bearing cup
from the end yoke.
14.The opening between the ears on the end yoke
is wider on one side. Remove the cross from the
side that has the wider opening.
15.Repeat Steps 10-14 to remove the cross from
the shaft yoke. Be careful not to hit the grease
fitting in the shaft yoke.