Calibration

Reference

Completed Calibration Event

A completed calibration event is any calibration
target that has been printed and analyzed. You can
reanalyze a target if the following are true:
✔ The calibration target was analyzed visually.
✔ There have been no other calibrations
completed for the printer and media
combination since the one that you want to
analyze.
Back
Contents

Approved Densitometers

Use densitometers with a Status A spectral
response with the ML-500 calibration application.
Densitometers with a Status T spectral response
are unsuitable for the ML-500 calibration
application.
The following densitometers are usable with the
calibration application:
* Only the 404 and 414 densitometers marked with
"A-RESP" are usable with the calibration
application.
Next
Index
✔ X-RITE 404 *
✔ X-RITE 414 *
✔ X-RITE DPT-36
✔ X-RITE DPT-41
✔ X-RITE 528
✔ X-RITE 530