Total Protection Solutions LoadTrack TK-LTL120P-30A Installation, Operation And Maintenance Manual

Surge protective devices

Advertisement

Quick Links

LoadTrack LTL
LOADTRACK LTL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL PN 750-0071-002 A00
Surge
Protective
Devices
Installation,
Operation and
Maintenance
Manual
P.O. Box 3760
Winter Park, FL 32790 US
TEL: 800-647-1911
www.TPSsurge.com

Advertisement

Table of Contents
loading

Summary of Contents for Total Protection Solutions LoadTrack TK-LTL120P-30A

  • Page 1 Surge Protective Devices LoadTrack LTL Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 US TEL: 800-647-1911 www.TPSsurge.com ™ LOADTRACK LTL INSTALLATION, OPERATION AND MAINTENANCE MANUAL PN 750-0071-002 A00...
  • Page 2: Table Of Contents

    T BLE OF CONTENTS Before Installation System Configuration Verification Pre-installation Checklist LoadTrack SPD Model Numbers Mounting Electrical Connections Service Configurations Single Phase Split-Phase Dimensional Specifications Standards and Listings Warranty Statement ™ LOADTRACK LTL INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
  • Page 3: Before Installation

    BEFORE INST LL TION WARNING: HAZARDOUS VOLTAGES PRESENT Improper installation or misapplication may result in serious personnel injury and/or damage to electrical system. Read the complete installation instructions before proceeding with installation. Remove all power to the electrical panel before installing or servicing the surge protective device (SPD).
  • Page 4: Mounting

    Mounting 1. The LoadTrack SPD is intended to be installed in a control cabinet or similar enclosure with a degree of protection of at least IP20 (NEMA 1). The enclosure shall provide protection against accidental contact by requiring a tool, key or similar device to ensure only Qualified Personnel are allowed access to exposed live (energized) circuits.
  • Page 5: Service Configurations

    Service Configurations Figure 1 Single-Phase Use only the L1 Terminal lug for the phase wires (input & output) when connecting a single-phase configuration. Figure 2 Split-Phase Match the corresponding L1 & L2 terminal lugs for the input & output phase wires when connecting a split-phase configuration. ™...
  • Page 6: Dimensional Specifications

    Dimensional Specifications Figure 3 0.38 in (9.7 mm) 0.185 in (47 mm) Two locations 0.25 in (6.4 mm) 5.77 in (147 mm) ST ND RDS ND LISTINGS • Listed by ETL to UL 1449 3rd Edition (2009 Revision), Type 4 for Type 2 SPD applications, cUL, and UL 1283 •...
  • Page 7: Warranty Statement

    Warranty period begins from date of original owner purchase. This warranty is not transferable and may only be enforced by the original end user. Claims under this warranty must be submitted to Total Protection Solutions within thirty (30) days of discovery of any suspected product defect.
  • Page 8 ® P.O. Box 3760 Winter Park, FL 32790 US www.TPSsurge.com 1.800.647.1911 ©2014 TOT L PROTECTION SOLUTIONS, LLC PRINTED IN US LL RIGHTS RESERVED PN 750-0071-002 01 072414...