WATER HEATING UNITS EQUIPPED FOR ONE VOLTAGE ONLY: CHECK THE RATING
PLATE ON THE FRONT OF THE UNIT. DO NOT USE THIS WATER HEATER WITH ANY
VOLTAGE OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE. FAILURE TO
DO SO CAN RESULT IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. IF
YOU HAVE ANY QUESTIONS OR DOUBTS CONSULT YOUR ELECTRIC COMPANY.
This unit must have its own independent circuit using five wires; three live,one neutral and
one ground of the appropriate rating protected by the correctly rated three pole breaker
MODEL
RATING(KW)
*EFT-18000-T-10
*EFT-24000-T-10
*EFT-18000-T-10
*EFT-24000-T-10
*EFT-32000-T-10
*EFT-28000-T-10
IF THE UNIT IS CONNECTED TO 460/265 THREE PHASE SYSTEM THE ABOVE OUTPUTS WILL BE REDUCED BY 8.5%
* UNIT MAY BE CONNECTED TO A 208V POWER SUPPLY, ABOVE OUTPUTS WILL BE REDUCED BY 25%
BEFORE SWITCHING "ON" THE POWER AT THE MAIN CIRCUIT BREAKER PANEL MAKE
SURE THAT THE HOT WATER CIRCUIT IS FREE OF AIR POCKETS OR PREMATURE
FAILURE OF THE ELEMENT WILL OCCUR. TO DO THIS OPEN ALL HOT WATER OUTLETS
ONE AT A TIME FOR A MINUTE OR TWO UNTIL THE WATER FLOW IS CONTINUOUS AND
FREE FROM "GULPING" AND FROM VISIBLE AIR POCKETS.

ELECTRICAL HOOK-UP

WARNING
RATINGS OF " EFT" THREE PHASE MODELS
CURRENT
VOLTAGE(V) PER PHASE 1.5GPM 2.0GPM 2.5GPM 3.0GPM 3.5GPM 4.0GPM 5.0GPM
18
208/120 50A/PHASE
24
208/120 67A/PHASE
18
277 21.7A/PHASE
24
277 28.9A/PHASE
32
277 38.5A/PHASE
28
240 40A/PHASE
82
61
0
82
82
61
0
82
0
128
90
IMPORTANT
5
TEMPERATURE RISE IN DEGREES
49
41
65
54
49
41
65
54
0
87
73
72
65
35
32
25
47
43
34
35
32
25
47
43
34
62
58
45
55
47
38