REPLACEMENT OF GAS VALVES
To replace gas valves, remove the hob, remove the two screws securing the manifold to the
base and release the compression joints on the output side of the gas valves.
Remove the screws clamping the gas valve to the manifold.
It is recommended that the manifold to gas valve gaskets be replaced whenever the valve is
disturbed.
Reverse the procedure for reassembly. Check the cooktop to ensure that there are no gas
leaks.
GREASING THE GAS VALVES
If the valves become difficult to operate, they should be greased as follows:
FIGURE 3
1.
Dismantle the valve body by removing the two
screws located in the body of the valve as shown in
Figure 3.
2.
Clean the cone and valve body with a solvent soaked
cloth. Lightly grease the cone with the appropriate
grease
3.
Insert the cone and operate the valve several times.
Remove the cone again and wipe away any excess
grease making certain that all ports are free from
obstruction.
4.
Reassemble and remount the valve.
6.
Check the cooktop to ensure that there are no gas
leaks