Technical Data; Gas Leaks - Whirlpool AKM160/IX Service Manual

Gas cooktop
Table of Contents

Advertisement

WHIRLPOOL CONSUMER SERVICES

TECHNICAL DATA

Burner
Gas
Type
Small
Propane
N.G.
Medium Propane
N.G.
Wok
Propane
N.G.
Note - 0.165 gas jets: 506152 has short castlation and 506128 (for large burner in other

GAS LEAKS

After performing any maintenance or service operation on the cooktop, the cooktop must be
checked to ensure that there are no gas leaks.
GAS JET REPLACEMENT
WARNING : Servicing must be carried out only by authorised personnel.
This appliance is approved by the Australian Gas Association for use with either natural gas
or propane gas. Ensure that appliance is suitable for the available gas supply.
To replace a gas jet, the following procedure applies:
FIGURE 1
Operating
Rating
Pressure
kPa
g/h
l/h
2.75
65
1.00
-
2.75
119
1.00
-
2.75
250
1.00
-
models) has longer castlation.
Gas Jet (Nozzle)
Diameter
Part No
1/100mm
-
50
506130
87
86
506126
-
68
506131
159
115
506127
-
102
506151
334
165
506152
1.
Turn off the gas cock adjacent to the
cooktop.
2.
Remove all the burners and unscrew the
jets using a 7mm socket. See Figure 1.
3.
Reinstall the jet appropriate to the gas
supply.
6.
Check the cooktop to ensure that there are
no gas leaks
M
odel AKM160/IX
Page 4 of 9
Output Power
kW
MJ/h
920
3.3
920
3.3
1670
6.0
16700
6.0
3500
12.6
3500
12.6

Hide quick links:

Advertisement

Table of Contents
loading